Please do not apply this to mainline directly, instead please re-run the
coccinelle script shown below and apply its output.
For several reasons, it is desirable to use {READ,WRITE}_ONCE() in
preference to ACCESS_ONCE(), and new code is expected to use one of the
former. So far, there's been no reason to change most existing uses of
ACCESS_ONCE(), as these aren't harmful, and changing them results in
churn.
However, for some features, the read/write distinction is critical to
correct operation. To distinguish these cases, separate read/write
accessors must be used. This patch migrates (most) remaining
ACCESS_ONCE() instances to {READ,WRITE}_ONCE(), using the following
coccinelle script:
----
// Convert trivial ACCESS_ONCE() uses to equivalent READ_ONCE() and
// WRITE_ONCE()
// $ make coccicheck COCCI=/home/mark/once.cocci SPFLAGS="--include-headers" MODE=patch
virtual patch
@ depends on patch @
expression E1, E2;
@@
- ACCESS_ONCE(E1) = E2
+ WRITE_ONCE(E1, E2)
@ depends on patch @
expression E;
@@
- ACCESS_ONCE(E)
+ READ_ONCE(E)
----
Signed-off-by: Mark Rutland <mark.rutland@arm.com>
Signed-off-by: Paul E. McKenney <paulmck@linux.vnet.ibm.com>
Cc: Linus Torvalds <torvalds@linux-foundation.org>
Cc: Peter Zijlstra <peterz@infradead.org>
Cc: Thomas Gleixner <tglx@linutronix.de>
Cc: davem@davemloft.net
Cc: linux-arch@vger.kernel.org
Cc: mpe@ellerman.id.au
Cc: shuah@kernel.org
Cc: snitzer@redhat.com
Cc: thor.thayer@linux.intel.com
Cc: tj@kernel.org
Cc: viro@zeniv.linux.org.uk
Cc: will.deacon@arm.com
Link: http://lkml.kernel.org/r/1508792849-3115-19-git-send-email-paulmck@linux.vnet.ibm.com
Signed-off-by: Ingo Molnar <mingo@kernel.org>
In IEC 61883-6, AM824 is described as format of data block. In this
format, one data block consists of several data channels, which is aligned
to 32 bit. One data channel has 8 bit label field and 24 bit data field.
PCM frames are transferred in Multi Bit Linear Audio (MBLA) data channel.
This channel can include 16/20/24 bit PCM sample.
As long as I know, models which support IEC 61883-1/6 doesn't allow to
switch bit length of PCM sample in MBLA data channel. They always
transmit/receive PCM frames of 24 bit length. This can be seen for the
other models which support protocols similar to IEC 61883-1/6.
On the other hand, current drivers for these protocols supports 16 bit
length PCM sample in playback substream. In this case, PCM sample is put
into the MBLA data channel with 8 bit padding in LSB side. Although 16
bit PCM sample is major because it's in CD format, this doesn't represent
device capability as is.
This commit removes support for 16 bit PCM samples in playback substream.
Signed-off-by: Takashi Sakamoto <o-takashi@sakamocchi.jp>
Acked-by: Clemens Ladisch <clemens@ladisch.de>
Signed-off-by: Takashi Iwai <tiwai@suse.de>
TASCAM FireWire series uses non-blocking transmission for AMDTP packet
streaming, while the format of data blocks is unique.
The CIP headers includes specific value in FMT field and no SYT
information.
In transmitted packets, the first data channel represents event counter,
and the last data channel has status and control information. The rest
has 24bit PCM samples with right padding.
In received packets, all of data channels include 16, 24, 32bit PCM
samples. There's no other kind of information.
This commit adds support for this protocol. For convenience, the size of
PCM samples in outgoing packet is limited by 16 and 24bit. The status and
control information will be supported in future commits.
Signed-off-by: Takashi Sakamoto <o-takashi@sakamocchi.jp>
Signed-off-by: Takashi Iwai <tiwai@suse.de>