This allows custom setup of IRQ coalescing for platforms using legacy
platform_device. The irq timeout and count parameters can be used for
tuning cpu load vs. latency.
I have maintained the 0x00000400 bit in TX_CHNL_CTRL. It is specified as
unused in the documentation I have available. It does not make any
difference in the hardware I have available, so it is left in to not risk
breaking other platforms where it might be used.
Signed-off-by: Esben Haabendal <esben@geanix.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Indirect register access goes through a DCR bus bridge, which
allows only one outstanding transaction. And to make matters
worse, each TEMAC IP block contains two Ethernet interfaces, and
although they seem to have separate registers for indirect access,
they actually share the registers. Or to be more specific, MSW, LSW
and CTL registers are physically shared between Ethernet interfaces
in same TEMAC IP, with RDY register being (almost) specificic to
the Ethernet interface. The 0x10000 bit in RDY reflects combined
bus ready state though.
So we need to take care to synchronize not only within a single
device, but also between devices in same TEMAC IP.
This commit allows to do that with legacy platform devices.
For OF devices, the xlnx,compound parent of the temac node should be
used to find siblings, and setup a shared indirect_mutex between them.
I will leave this work to somebody else, as I don't have hardware to
test that. No regression is introduced by that, as before this commit
using two Ethernet interfaces in same TEMAC block is simply broken.
Signed-off-by: Esben Haabendal <esben@geanix.com>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Signed-off-by: David S. Miller <davem@davemloft.net>
Replace the powerpc specific MMIO register access functions with the
generic big-endian mmio access functions, and add support for
little-endian access depending on configuration.
Big-endian access is maintained as the default, but little-endian can
be configured in device-tree binding or in platform data.
The temac_ior()/temac_iow() functions are replaced with macro wrappers
to avoid modifying existing code more than necessary.
Signed-off-by: Esben Haabendal <esben@geanix.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Support initialization with platdata, so the driver can be used on
non-device-tree platforms.
For currently supported device-tree platforms, the driver should behave
as before.
Signed-off-by: Esben Haabendal <esben@geanix.com>
Signed-off-by: David S. Miller <davem@davemloft.net>