eth_change_mtu() is not needed any more, the networking subsystem will
call it automatically when this callback is not implemented.
Signed-off-by: Hauke Mehrtens <hauke@hauke-m.de>
Signed-off-by: David S. Miller <davem@davemloft.net>
Return 'err' in the error handling path instead of 0.
Return explicitly 0 in the normal path, instead of 'err', which is known
to be 0 at this point.
Fixes: fe1a56420c ("net: lantiq: Add Lantiq / Intel VRX200 Ethernet driver")
Signed-off-by: Christophe JAILLET <christophe.jaillet@wanadoo.fr>
Signed-off-by: David S. Miller <davem@davemloft.net>
The switch and the MAC are in one IP core and they use the same clock
signal from the clock generation unit.
Currently the clock architecture in the lantiq SoC code does not allow
to easily share the same clocks, this has to be fixed by switching to
the common clock framework.
As a workaround the clock of the switch and MAC should be activated when
the MAC gets probed and only disabled when the MAC gets removed. This
way it is ensured that the clock is always enabled when the switch or
MAC is used. The switch can not be used without the MAC.
This fixes a data bus error when rebooting the system and deactivating
the switch and mac and later accessing some registers in the cleanup
while the clocks are disabled.
Fixes: fe1a56420c ("net: lantiq: Add Lantiq / Intel VRX200 Ethernet driver")
Signed-off-by: Hauke Mehrtens <hauke@hauke-m.de>
Signed-off-by: David S. Miller <davem@davemloft.net>
In case of error, the function devm_ioremap_resource() returns ERR_PTR()
and never returns NULL. The NULL test in the return value check should
be replaced with IS_ERR().
Fixes: fe1a56420c ("net: lantiq: Add Lantiq / Intel VRX200 Ethernet driver")
Signed-off-by: Wei Yongjun <weiyongjun1@huawei.com>
Acked-by: Hauke Mehrtens <hauke@hauke-m.de>
Signed-off-by: David S. Miller <davem@davemloft.net>
This drives the PMAC between the GSWIP Switch and the CPU in the VRX200
SoC. This is currently only the very basic version of the Ethernet
driver.
When the DMA channel is activated we receive some packets which were
send to the SoC while it was still in U-Boot, these packets have the
wrong header. Resetting the IP cores did not work so we read out the
extra packets at the beginning and discard them.
This also adapts the clock code in sysctrl.c to use the default name of
the device node so that the driver gets the correct clock. sysctrl.c
should be replaced with a proper common clock driver later.
Signed-off-by: Hauke Mehrtens <hauke@hauke-m.de>
Signed-off-by: David S. Miller <davem@davemloft.net>