The check for old hardware versions that did not have SMCDv2 support was
using suspicious pointer magic. Address the fields using an array.
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
SMCD Version 2 allows to propose up to 8 additional ISM devices
offered to the peer as candidates for SMCD communication.
This patch covers determination of the ISM devices to be proposed.
ISM devices without PNETID are preferred, since ISM devices with
PNETID are a V1 leftover and will disappear over the time.
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
With SMCD version 2 the CHIDs of ISM devices are needed for the
CLC handshake.
This patch provides the new callback to retrieve the CHID of an
ISM device.
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
SMCD version 2 defines a System Enterprise ID (short SEID).
This patch contains the SEID creation and adds the callback to
retrieve the created SEID.
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
The similar smc_ib_devices spinlock has been converted to a mutex.
Protecting the smcd_dev_list by a mutex is possible as well. This
patch converts the smcd_dev_list spinlock to a mutex.
Fixes: c6ba7c9ba4 ("net/smc: add base infrastructure for SMC-D and ISM")
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Print to system log when SMC links are available or go down, link group
state changes or pnetids are applied to and removed from devices.
The log entries are triggered by either user configuration actions or
adapter activation/deactivation events and are not expected to happen
often. The entries help SMC users to keep track of the SMC link group
status and to detect when actions are needed (like to add replacements
for failed adapters).
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Reviewed-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
The pnet table stored pnet ids in the smc device structures. When a
device is going down its smc device structure is freed, and when the
device is brought online again it no longer has a pnet id set.
Rework the pnet table implementation to store the device name with their
assigned pnet id and apply the pnet id to devices when they are
registered.
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Reviewed-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
If the ism module is unloaded return control from exit routine only,
if all link groups are freed.
If an IB device is thrown away return control from device removal only,
if all link groups belonging to this device are freed.
A counters for the total number of SMCD link groups per ISM device is
introduced. ism module unloading continues only if the total number of
SMCD link groups for all ISM devices is zero. ISM device
removal continues only it the total number of SMCD link groups per ISM
device has decreased to zero.
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
A final cleanup due to SMCD device removal means immediate freeing
of all link groups belonging to this device in interrupt context.
This patch introduces a separate SMCD link group termination routine,
which terminates all link groups of an SMCD device.
This new routine smcd_terminate_all ()is reused if the smc module is
unloaded.
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
SMCD link group termination is called when peer signals its shutdown
of its corresponding link group. For regular shutdowns no connections
exist anymore. For abnormal shutdowns connections must be killed and
their DMBs must be unregistered immediately. That means the SMCR method
to delay the link group freeing several seconds does not fit.
This patch adds immediate termination of a link group and its SMCD
connections and makes sure all SMCD link group related cleanup steps
are finished.
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
If peer announces shutdown, use the link group terminate worker for
local cleanup of link groups and connections to terminate link group
in proper context.
Make sure link groups are cleaned up first before destroying the
event queue of the SMCD device, because link group cleanup may
raise events.
Send signal shutdown only if peer has not done it already.
Send socket abort or close only, if peer has not already announced
shutdown.
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Add a "going_away" indication to ISM devices and IB ports and
avoid creation of new connections on such disappearing devices.
And do not handle ISM events if ISM device is disappearing.
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: Jakub Kicinski <jakub.kicinski@netronome.com>
This patch introduces separate locks for the split SMCD and SMCR
link group lists.
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: Jakub Kicinski <jakub.kicinski@netronome.com>
Currently SMCD and SMCR link groups are maintained in one list.
To facilitate abnormal termination handling they are split into
a separate list for SMCR link groups and separate lists for SMCD
link groups per SMCD device.
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: Karsten Graul <kgraul@linux.ibm.com>
Signed-off-by: Jakub Kicinski <jakub.kicinski@netronome.com>
In case alloc_ordered_workqueue fails, the fix returns NULL
to avoid NULL pointer dereference.
Signed-off-by: Kangjie Lu <kjlu@umn.edu>
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
When a SMC-D link group is freed, a shutdown signal should be sent to
the peer to indicate that the link group is invalid. This patch adds the
shutdown signal to the SMC code.
Signed-off-by: Hans Wippel <hwippel@linux.ibm.com>
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
With SMC-D z/OS sends a test link signal every 10 seconds. Linux is
supposed to answer, otherwise the SMC-D connection breaks.
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
The data transfer and CDC message headers differ in SMC-R and SMC-D.
This patch adds support for the SMC-D data transfer to the existing SMC
code. It consists of the following:
* SMC-D CDC support
* SMC-D tx support
* SMC-D rx support
The CDC header is stored at the beginning of the receive buffer. Thus, a
rx_offset variable is added for the CDC header offset within the buffer
(0 for SMC-R).
Signed-off-by: Hans Wippel <hwippel@linux.ibm.com>
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Suggested-by: Thomas Richter <tmricht@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
SMC-D relies on PNETIDs to find usable SMC-D/ISM devices for a SMC
connection. This patch adds SMC-D/ISM support to the current PNETID
implementation.
Signed-off-by: Hans Wippel <hwippel@linux.ibm.com>
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Suggested-by: Thomas Richter <tmricht@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
SMC supports two variants: SMC-R and SMC-D. For data transport, SMC-R
uses RDMA devices, SMC-D uses so-called Internal Shared Memory (ISM)
devices. An ISM device only allows shared memory communication between
SMC instances on the same machine. For example, this allows virtual
machines on the same host to communicate via SMC without RDMA devices.
This patch adds the base infrastructure for SMC-D and ISM devices to
the existing SMC code. It contains the following:
* ISM driver interface:
This interface allows an ISM driver to register ISM devices in SMC. In
the process, the driver provides a set of device ops for each device.
SMC uses these ops to execute SMC specific operations on or transfer
data over the device.
* Core SMC-D link group, connection, and buffer support:
Link groups, SMC connections and SMC buffers (in smc_core) are
extended to support SMC-D.
* SMC type checks:
Some type checks are added to prevent using SMC-R specific code for
SMC-D and vice versa.
To actually use SMC-D, additional changes to pnetid, CLC, CDC, etc. are
required. These are added in follow-up patches.
Signed-off-by: Hans Wippel <hwippel@linux.ibm.com>
Signed-off-by: Ursula Braun <ubraun@linux.ibm.com>
Suggested-by: Thomas Richter <tmricht@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>