Every device tested so far got UART0 (at 0x18000300) working as serial
console. It's most likely part of reference design and all vendors use
it that way.
It seems to be easier to enable it by default and just disable it if we
ever see a device with different hardware design.
Signed-off-by: Rafał Miłecki <rafal@milecki.pl>
Acked-by: Jon Mason <jon.mason@broadcom.com>
Acked-by: Hauke Mehrtens <hauke@hauke-m.de>
Signed-off-by: Florian Fainelli <f.fainelli@gmail.com>
Controller is present on every BCM4708* board but only few devices have
serial flash attached so mark it as disabled by default.
Signed-off-by: Rafał Miłecki <zajec5@gmail.com>
Signed-off-by: Florian Fainelli <f.fainelli@gmail.com>
There are two possible UARTs so we have (both of) them disabled by
default. Override uart0 status on devices that were verified to use it.
In case of Netgear R6250 also drop an old (and invalid) overwrite. It
doesn't have uart1 connected.
Signed-off-by: Rafał Miłecki <zajec5@gmail.com>
Acked-by: Hauke Mehrtens <hauke@hauke-m.de>
Signed-off-by: Florian Fainelli <f.fainelli@gmail.com>
This adds the NAND flash chip description for a standard chip found
connected to this SoC. This makes use of generic Broadcom NAND driver
with the iProc interface.
Signed-off-by: Hauke Mehrtens <hauke@hauke-m.de>
Signed-off-by: Florian Fainelli <f.fainelli@gmail.com>
Luxul XWC-1000 is a controller device based on BCM4708 SoC. The only
unusual thing in its DTS file is "ubi" partition on NAND flash.
Signed-off-by: Dan Haab <dhaab@luxul.com>
Signed-off-by: Hauke Mehrtens <hauke@hauke-m.de>