The KDIV value is often listed as unsigned but it needs to be treated
as a 16-bit signed value when using it in calculations. Fix our rate
recalculation to do this correctly.
Before doing this, I tried setting EPLL on exynos5250 to:
rate, m, p, s, k = 80000000, 107, 2, 4, 43691
This rate is exactly from the table in the exynos5250 user manual.
I read this back as 80750003 with:
cat /sys/kernel/debug/clk/fin_pll/fout_epll/clk_rate
After this patch, it reads back as 80000003
Signed-off-by: Doug Anderson <dianders@chromium.org>
Acked-by: Kukjin Kim <kgene.kim@samsung.com>
Reviewed-by: Vikas Sajjan <vikas.sajjan@linaro.org>
Signed-off-by: Mike Turquette <mturquette@linaro.org>
Unimplemented clock operations should be simply omitted instead of returning
error values.
This patch removes unimplemented PLL operations to fix problems caused
by returning error code in round_rate callback.
Signed-off-by: Tomasz Figa <t.figa@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Reviewed-by: Thomas Abraham <thomas.abraham@linaro.org>
Acked-by: Mike Turquette <mturquette@linaro.org>
Signed-off-by: Kukjin Kim <kgene.kim@samsung.com>
There are several types of pll clocks used in Samsung SoC's and these
pll clocks can be represented as Samsung specific pll clock types and
registered with the common clock framework. Add support for pll35xx,
pll36xx, pll45xx, pll46xx and pll2550x clock types and helper functions
to register them.
Reviewed-by: Sylwester Nawrocki <s.nawrocki@samsung.com>
Tested-by: Sylwester Nawrocki <s.nawrocki@samsung.com>
Reviewed-by: Tomasz Figa <t.figa@samsung.com>
Tested-by: Tomasz Figa <t.figa@samsung.com>
Signed-off-by: Thomas Abraham <thomas.abraham@linaro.org>
Acked-by: Mike Turquette <mturquette@linaro.org>
Signed-off-by: Kukjin Kim <kgene.kim@samsung.com>