The BerliOS project, which currently hosts our mailinglist, will
close with the end of the year. Now take the chance and remove all
occurrences of the mailinglist address from the source files.
Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de>
Signed-off-by: David S. Miller <davem@davemloft.net>
This patch makes the bus-error reporting configurable and allows to
retrieve the CAN TX and RX bus error counters via netlink interface.
I have added support for the SJA1000. The TX and RX bus error counters
are also copied to the data fields 6..7 of error messages when state
changes are reported.
Signed-off-by: Wolfgang Grandegger <wg@grandegger.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
This patch adds the flag CAN_CTRLMODE_ONE_SHOT. It is used as mask
or flag in the "struct can_ctrlmode".
It allows userspace via netlink to set a CAN controller into the special
"one-shot" mode. In this mode, if supported by the CAN controller, it
tries only once to deliver a CAN frame and aborts it if an error
(e.g.: arbitration lost) happens.
Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de>
Acked-by: Wolfgang Grandegger <wg@grandegger.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
The CAN network device driver interface provides a generic interface to
setup, configure and monitor CAN network devices. It exports a set of
common data structures and functions, which all real CAN network device
drivers should use. Please have a look to the SJA1000 or MSCAN driver
to understand how to use them. The name of the module is can-dev.ko.
Furthermore, it adds a Netlink interface allowing to configure the CAN
device using the program "ip" from the iproute2 utility suite.
For further information please check "Documentation/networking/can.txt"
Signed-off-by: Wolfgang Grandegger <wg@grandegger.com>
Signed-off-by: Oliver Hartkopp <oliver.hartkopp@volkswagen.de>
Signed-off-by: David S. Miller <davem@davemloft.net>