Prematurely decrementing the reference may lead to cmd_mgr becoming NULL with
the cmds are still active.
Signed-off-by: Nithin Nayak Sujir <nsujir@broadcom.com>
Signed-off-by: Bhanu Prakash Gollapudi <bprakash@broadcom.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Creating and destroying fcoe interface in a tight loop leads to a system
deadlock with the following call traces:
Call Trace:
[<ffffffff814f4b3d>] schedule_timeout+0x1fd/0x2c0
[<ffffffff814f469f>] ? wait_for_common+0x4f/0x190
[<ffffffff814f469f>] ? wait_for_common+0x4f/0x190
[<ffffffff814f4737>] wait_for_common+0xe7/0x190
[<ffffffff81042fa0>] ? default_wake_function+0x0/0x20
[<ffffffff81082c2d>] ? trace_hardirqs_on+0xd/0x10
[<ffffffff814f48bd>] wait_for_completion+0x1d/0x20
[<ffffffff81066d90>] flush_workqueue+0x290/0x5f0
[<ffffffff81066b00>] ? flush_workqueue+0x0/0x5f0
[<ffffffff81067148>] destroy_workqueue+0x38/0x340
[<ffffffffa0260289>] fc_remove_host+0x1b9/0x1f0 [scsi_transport_fc]
[<ffffffffa02ed195>] bnx2fc_if_destroy+0xc5/0x1f0 [bnx2fc]
[<ffffffffa02ed33a>] bnx2fc_destroy+0x7a/0x100 [bnx2fc]
[<ffffffffa02c789b>] fcoe_transport_destroy+0x9b/0x1b0 [libfcoe]
[<ffffffff81069ec2>] param_attr_store+0x52/0x80
[<ffffffff81069976>] module_attr_store+0x26/0x30
[<ffffffff8119e726>] sysfs_write_file+0xe6/0x170
[<ffffffff81134710>] vfs_write+0xd0/0x1a0
[<ffffffff811348e4>] sys_write+0x54/0xa0
[<ffffffff81002e02>] system_call_fastpath+0x16/0x1b
Call Trace:
[<ffffffff81074865>] async_synchronize_cookie_domain+0x75/0x120
[<ffffffff8106caa0>] ? autoremove_wake_function+0x0/0x40
[<ffffffff81074925>] async_synchronize_cookie+0x15/0x20
[<ffffffff8107494c>] async_synchronize_full+0x1c/0x40
[<ffffffffa0057466>] sd_remove+0x36/0xc0 [sd_mod]
[<ffffffff81358a75>] __device_release_driver+0x75/0xe0
[<ffffffff81358bef>] device_release_driver+0x2f/0x50
[<ffffffff81357aee>] bus_remove_device+0xbe/0x120
[<ffffffff813553ef>] device_del+0x12f/0x1e0
[<ffffffff8137454d>] __scsi_remove_device+0xbd/0xc0
[<ffffffff81374585>] scsi_remove_device+0x35/0x50
[<ffffffff813746a7>] __scsi_remove_target+0xe7/0x110
[<ffffffff81374730>] ? __remove_child+0x0/0x30
[<ffffffff81374753>] __remove_child+0x23/0x30
[<ffffffff81354a2c>] device_for_each_child+0x4c/0x80
[<ffffffff81374703>] scsi_remove_target+0x33/0x60
[<ffffffffa02622c6>] fc_starget_delete+0x26/0x30 [scsi_transport_fc]
[<ffffffffa026271a>] fc_rport_final_delete+0xaa/0x200 [scsi_transport_fc]
[<ffffffff8106585a>] process_one_work+0x1aa/0x540
[<ffffffff810657eb>] ? process_one_work+0x13b/0x540
[<ffffffffa0262670>] ? fc_rport_final_delete+0x0/0x200 [scsi_transport_fc]
[<ffffffff81067ac9>] worker_thread+0x179/0x410
[<ffffffff81067950>] ? worker_thread+0x0/0x410
[<ffffffff8106c546>] kthread+0xb6/0xc0
[<ffffffff8103879b>] ? finish_task_switch+0x4b/0xe0
[<ffffffff81003ca4>] kernel_thread_helper+0x4/0x10
[<ffffffff814f7994>] ? restore_args+0x0/0x30
[<ffffffff8106c490>] ? kthread+0x0/0xc0
[<ffffffff81003ca0>] ? kernel_thread_helper+0x0/0x10
fc_remove_host() waits for flushing the workqueue, but it is stuck at flushing
the first work. The first work doesnt complete, because it is waiting for async
layer to complete the IOs. The async layer cannot complete the IO as the
terminate_rport_io for the second work was not called, which will be called
only when the first work completes. Hence the deadlock. To resolve this
deadlock, the workqueue allocation has been modified from
create_singlethread_workqueue() to alloc_workqueue().
In addition, fc_terminate_rport_io() should be called before the
scsi_flush_work() to avoid the similar deadlock as above.
scsi fc alloc queue. move terminate rport io before flush
Signed-off-by: Nithin Nayak Sujir <nsujir@broadcom.com>
Signed-off-by: Bhanu Prakash Gollapudi <bprakash@broadcom.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Update driver version to 8.3.22
Signed-off-by: Alex Iannicelli <alex.iannicelli@emulex.com>
Signed-off-by: James Smart <james.smart@emulex.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
- Fixed the mixed declarations and codes which violate ISO C90
(declarations in subsections that assign at declaration)
- Add BSG data transfer size protection in mailbox command pass-through path
- Invoke BSG job_done while holding spinlock to fix deadlock
- Added support for checking SLI_CONFIG subcommands
- Fixed bug in BSG mailbox size check to non-embedded external buffer
Signed-off-by: Alex Iannicelli <alex.iannicelli@emulex.com>
Signed-off-by: James Smart <james.smart@emulex.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Fixes related to new hardware
- Restrict driver to look at BAR2 or BAR4 only for if_type 0.
- Allow SLI4 with FCOE_MODE not set for new SLI4 FC adapters.
- Add Temporary RPI field to the ELS request WQE.
- Do not override CT field in issue_els_flogi for SLI4 IF type 2
- For RQ_CREATE_V2 mbx cmd: fill in the rqe_size and page_size for RQ_CREATE.
Signed-off-by: Alex Iannicelli <alex.iannicelli@emulex.com>
Signed-off-by: James Smart <james.smart@emulex.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Miscellaneous fixes
- Do not limit RPI Count to a minimum of 64
- Fix FCFI incorrect on received unsolicited frames.
- Save the FCFI returned in the REG_FCFI mailbox command if it was successful.
- Fixed Vports not sending FDISC after lips.
- Align based on the SLI4_PAGE_SIZE.
- Fixed double byte swap on received RRQ.
- Fixed mask size for the wq_id mask from 0x7F to 0x7FFF.
- Clear FC_FABRIC flag when NPIV LOGO completes (and add a log message).
- Modified driver to skip round robin only when ulpStatus==LOCAL_REJECT
and word4=SEQUENCE_TIMEOUT to prevent FLOGI to disconnected FCF.
- Don't add rport if driver unloading
Signed-off-by: Alex Iannicelli <alex.iannicelli@emulex.com>
Signed-off-by: James Smart <james.smart@emulex.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Debugfs enhancements
- Added iDiag support for new adapters.
- Added queue entry access methods.
- Fix host/port index in decimal
- Added Doorbell register access methods.
Signed-off-by: Alex Iannicelli <alex.iannicelli@emulex.com>
Signed-off-by: James Smart <james.smart@emulex.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Move the initialization of debugfs before bfa init, to enable us to
collect driver/firmware traces if init fails. Also add a printk to
display message on bfa_init failure.
Signed-off-by: Krishna Gudipati <kgudipat@brocade.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This patch includes fixes for two issues releated to firmware download
implementation: 1) Merged memory leak fix provided by Jesper Juhl
<jj@chaosbits.net>. Basically we need to call release_firmware() after
request_firmware(). 2) fixed issues with the firmware download interface
as pointed out by Rolf Eike Beer <eike@sf-mail.de> in linux-scsi. Rearranged
the code and fixed related function protypes.
Signed-off-by: Jing Huang <huangj@brocade.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
During performance testing on P7 machines it was observed that the interrupt
service routine was doing unnecessary MMIO operations.
This patch rearranges the logic of the routine and moves some of the code out
of the main routine. The result is that there are now fewer MMIO operations in
the performance path of the code.
As a result of the above change, an existing condition was exposed where the
driver could get an "unexpected" hrrq interrupt. The original code would flag
the interrupt as unexpected and then reset the adapter. After further analysis
it was confirmed that this condition can occasionally occur and that the
interrupt can safely be ignored. Additional code in this patch detects this
condition, clears the interrupt and allows the driver to continue without
resetting the adapter.
Signed-off-by: Wayne Boyer <wayneb@linux.vnet.ibm.com>
Acked-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Based on the operating modes, handler decides whether to send mode
select or not. Purpose here is to reduce io-shipping as much as
possible whenever there is an option.
Signed-off-by: Babu Moger <babu.moger@lsi.com>
Reviewed-by: Yanling Qi <yanling.qi@lsi.com>
Reviewed-by: Sudhir Dachepalli <Sudhir.Dachepalli@lis.com>
Reviewed-by: Somasundaram Krishnasamy <Somasundaram.Krishnasamy@lsi.com>
Reviewed-by: Bob Stankey <Robert.Stankey@lsi.com>
Reviewed-by: Vijay Chauhan <Vijay.Chauhan@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This patch detects different operating RDAC modes during the
discovery. It also collects the information about the preferred path.
Signed-off-by: Babu Moger <babu.moger@lsi.com>
Reviewed-by: Yanling Qi <yanling.qi@lsi.com>
Reviewed-by: Sudhir Dachepalli <Sudhir.Dachepalli@lis.com>
Reviewed-by: Somasundaram Krishnasamy <Somasundaram.Krishnasamy@lsi.com>
Reviewed-by: Bob Stankey <Robert.Stankey@lsi.com>
Reviewed-by: Vijay Chauhan <Vijay.Chauhan@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This patch adds definitions to support for different operating modes
for LSI rdac storage. Currently, rdac support 3 operation modes.
1. RDAC mode(legacy)
2. AVT mode
3. IOSHIP mode
These definitions are used while activating the path(rdac_activate).
Signed-off-by: Babu Moger <babu.moger@lsi.com>
Reviewed-by: Yanling Qi <yanling.qi@lsi.com>
Reviewed-by: Sudhir Dachepalli <Sudhir.Dachepalli@lis.com>
Reviewed-by: Somasundaram Krishnasamy <Somasundaram.Krishnasamy@lsi.com>
Reviewed-by: Bob Stankey <Robert.Stankey@lsi.com>
Reviewed-by: Vijay Chauhan <Vijay.Chauhan@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This patch removes three volatile declarations based on some feedback and code
analysis.
Signed-off-by: Wayne Boyer <wayneb@linux.vnet.ibm.com>
Acked-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This patch has Support for the new solid state device product SSS6200
from LSI and relavent features w.r.t SSS6200.
The major feature added in this driver is supporting Direct-I/O to the
SSS6200 storage.There are some additional changes done to avoid exposing
the RAID member disks to the OS and hiding/exposing drives based on the
OEM Specific Flag in Manufacturing Page10 (this is required to handle
specific changes in the SSS6200 firmware).
Each and every changes are listed below.
1. Hiding IR related messages.
For SSS6200, the driver is modified not to print IR related events.
Even if the debugging is enabled the IR related messages will not be displayed.
In some places if there is a need to display a message related to IR the
string "IR" is replaced with string "DD" and the string "volume" is replaced
with "direct drive". But the function names are not changed hence there are
some places where the reference to volume can be seen if debug level is set.
2. Removed RAID transport support
In Linux the user can retrieve RAID volume information from the sysfs directory.
This support is removed for SSS6200.
3. Direct I/O support.
The driver tries to enable direct I/O when a volume is reported to the driver
by the firmware through IRCC events and the driver does this just before
reporting to the OS, hence all the OS issued I/O can go through direct path
if they can, The first validation is to see whether the manufacturing page10
flag is set to expose all drives always. If that is set, the driver will not
enable direct I/O and displays the message "DDIO" is disabled globally as
drives are exposed. The driver checks whether there is more than one volume
in the controller, if so the direct I/O will be disabled globally for all
volumes in the controller and the message displayed will be "DDIO is disabled
globally as number of drives > 1.
If retrieving number of PD is failed the driver will not enable direct I/O
and displays the message Failure in computing number of drives DDIO disabled.
If memory allocation for RAIDVolumePage0 is failed, the driver will not enable
direct I/O and displays the message Memory allocation failure for
RVPG0 DDIO disabled. If retrieving RAIDVolumePage0 is failed the driver will
not enable direct I/O and displays the message Failure in retrieving
RVPG0 DDIO disabled
If the number of PD in a volume is greater than 8, then the direct I/O will
be disabled.
If any of individual drives handle retrieval is failed then the DD-IO will
be disabled.
If the volume is not RAID0 or if the block size is not 512 then the DD-IO will
be disabled.
If the volume size is greater than 2TB then the DD-IO will be disabled.
If the driver is not able to find a valid stripe exponent using the configured
stripe size then the DD-IO will be disabled
When the DD-IO is enabled the driver will check every I/O request issued to
the storage and checks whether the request is either
READ6/WRITE6/READ10/WRITE10, if it is and if the complete I/O transfer
is within a stripe size then the I/O is redirected to
the drive directly instead of the volume.
On completion of every I/O, if the completion is failure means if the reply
is address reply with a reply frame associated with it, then the type of I/O
will be checked, if the I/O is direct then the I/O will be retried to
the volume once.
Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com>
Reviewed-by: Eric Moore <eric.moore@lsi.com>
Reviewed-by: Sathya Prakash <sathya.prakash@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The SCSI midlayer stops all command processing when in error handling, which
means there is no chance for command reuse when the abort handler is called.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Acked-by: "Moore, Eric" <Eric.Moore@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Currently fcoe interface cleanup is done after ndo_fcoe_disable
and that prevents logoff going out to the peer, so this patch
moves all netdev cleanup and its releasing inside
fcoe_interface_cleanup to have log off before ndo_fcoe_disable
disables the fcoe.
This patch also fixes asymmetric rtnl locking around fcoe_if_destroy,
as currently this function requires rtnl held by its caller
and then have this func drops the lock, instead now don't have
any processing under rtnl inside fcoe_if_destroy, this required
moving few func to get build working again.
Signed-off-by: Vasu Dev <vasu.dev@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Added REC_TOV_CONST intent was to have rec tov as e_d_tov + 1s
but currently it is e_d_tov + 1ms since e_d_tov is stored in ms
unit.
Also returned rec tov by get_fsp_rec_tov is in ms and this ms tov
is used as-is with fc_fcp_timer_set expecting jiffies tov.
Fixed this by having get_fsp_rec_tov return rec tov in jiffies
as e_d_tov + 1s and then use jiffies tov w/ fc_fcp_timer_set.
Also some cleanup, no need to cache get_fsp_rec_tov return value
in local rec_tov at various places.
Signed-off-by: Vasu Dev <vasu.dev@intel.com>
Tested-by: Ross Brattain <ross.b.brattain@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
As ema_list is already initialized by libfc_host_alloc.
Signed-off-by: Vasu Dev <vasu.dev@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
fix typo of '_attach' -> '_detach' in the comment.
Reported-by: Frank Zhang <frank_1.zhang@intel.com>
Signed-off-by: Yi Zou <yi.zou@intel.com>
Tested-by: Ross Brattain <ross.b.brattain@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
possible buffer overflow in fcoe_transport_show when reaching the end of
buffer and crossing PAGE_SIZE boundary.
Signed-off-by: Yi Zou <yi.zou@intel.com>
Signed-off-by: Tomas Henzl <thenzl@redhat.com>
Tested-by: Ross Brattain <ross.b.brattain@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
When rmmoving the underlying fcoe transport driver module by force when
it's attached and in use, the correspoding netdev mapping should be
cleaned up properly as well, otherwise the lookup for a given netdev
for the transport would still return non NULL pointer, causing "unable
to handle paging request" bug.
Signed-off-by: Yi Zou <yi.zou@intel.com>
Tested-by: Ross Brattain <ross.b.brattain@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The host_lock is still used to protect the can_queue
value in the Scsi_Host, but it doesn't need to be held
and released by each caller. This patch moves the lock
usage into the fc_fcp_can_queue_ramp_up and
fc_fcp_can_queue_ramp_down routines.
Signed-off-by: Robert Love <robert.w.love@intel.com>
Tested-by: Ross Brattain <ross.b.brattain@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Signed-off-by: Kirill A. Shutemov <kirill@shutemov.name>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The check of module state being MODULE_STATE_LIVE is no longer needed for the
individual fcoe transport driver, e.g., fcoe.ko, as sysfs entries now go to
libfcoe now, if it reaches fcoe.ko, it has to be already registered. The module
state check for libfcoe will guard the possible race condition of sysfs being
writable before module_init function is called and after module_exit.
Signed-off-by: Yi Zou <yi.zou@intel.com>
Tested-by: Ross Brattain <ross.b.brattain@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
These checks were initially added to avoid a lockdep
false positive when dealing with the s_active, rtnl
and fcoe_config_mutex mutexes. Recently the create,
destroy, enable and disable sysfs entries were moved
from fcoe.ko to libfcoe.ko. With this change the mutex
usage was shuffled around and the lockdep false
positive stopped happening. We can now remove these
checks.
Signed-off-by: Robert Love <robert.w.love@intel.com>
Tested-by: Ross Brattain <ross.b.brattain@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This code was incorrectly ported from fcoe.c when the
fcoe transport infrastructure was put into place. It
was originally needed in fcoe.c when dealing with
the rtnl mutex. In that code it was only needed to
avoid a lockdep false positive. In libfcoe we don't
deal with the rtnl mutex, we don't get the lockdep
false positive and therefore we don't need these
checks.
Signed-off-by: Robert Love <robert.w.love@intel.com>
Tested-by: Ross Brattain <ross.b.brattain@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
In testing it was noticed that Extended Delay after Reset flag was being set
for gscsi and volume set devices. This had a negative effect on performance
for volume sets. The fix is to only set the flag for gscsi devices.
Signed-off-by: Wayne Boyer <wayneb@linux.vnet.ibm.com>
Acked-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
A minor change in the versioning. We'll be attaching the "-k"
in the end.
Signed-off-by: Madhuranath Iyengar <Madhu.Iyengar@qlogic.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Add the inline function qla2x00_set_port_state() so that when a fcport state
transition happens we can log the state transition if debug messages are
enabled.
Signed-off-by: Chad Dupuis <chad.dupuis@qlogic.com>
Signed-off-by: Madhuranath Iyengar <Madhu.Iyengar@qlogic.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Before driver's own internal state is marked as PLOGI/PRLI
complete. This additional check closes a window seen with
dual-personality initiator/target devices where a driver's
PLOGI/PRLI request occurs within the window after the target's
PLOGI request has completed, but prior to the target's PRLI
arriving and processed by the firmware. Without this additional
check, the firmware will return port-information stating that the
port neither supports target nor initiator functions, causing the
driver to register the rport prematurely to the FC-transport
without the proper 'roles' being set.
Signed-off-by: Andrew Vasquez <andrew.vasquez@qlogic.com>
Signed-off-by: Giridhar Malavali <giridhar.malavali@qlogic.com>
Signed-off-by: Madhuranath Iyengar <Madhu.Iyengar@qlogic.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Also, change the ISP82xx code to only reset if this module_param is set
and reset is intended via the QLA82XX_DEV_NEED_RESET case.
Signed-off-by: Giridhar Malavali <giridhar.malavali@qlogic.com>
Signed-off-by: Madhuranath Iyengar <Madhu.Iyengar@qlogic.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
If fabric device has invalid loop id (FC_NO_LOOP_ID) then call
qla2x00_find_new_loop_id() to attempt to obtain valid loop id.
Signed-off-by: Joe Carnuccio <joe.carnuccio@qlogic.com>
Signed-off-by: Madhuranath Iyengar <Madhu.Iyengar@qlogic.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
For certain failures, try to recover first by doing FCoE context reset before
attempting big hammer approach(adpater reset).
Signed-off-by: Giridhar Malavali <giridhar.malavali@qlogic.com>
Signed-off-by: Madhuranath Iyengar <Madhu.Iyengar@qlogic.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The stanadlone call to qla82xx_check_fw_alive() in qla82xx_watchdog()
is a typo, so remove it.
Signed-off-by: Giridhar Malavali <giridhar.malavali@qlogic.com>
Signed-off-by: Madhuranath Iyengar <Madhu.Iyengar@qlogic.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The upper 16-bits of the handle for all I/O in multi-queue supported
drivers carries the ID of the request queue it was submitted on. When
using Abort I/O IOCB, the driver needs to also populate the upper
16-bits in the handle_to_abort field so the fw can correlate with the
actual I/O.
Signed-off-by: Mike Hernandez <michael.hernandez@qlogic.com>
Signed-off-by: Madhuranath Iyengar <Madhu.Iyengar@qlogic.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The bit is already set upon entry.
Signed-off-by: Andrew Vasquez <andrew.vasquez@qlogic.com>
Signed-off-by: Madhuranath Iyengar <Madhu.Iyengar@qlogic.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Modifying qla24xx_get_fcp_prio() to return a 'found' status
allows the driver to short circuit the 'set FCP-priority' call
and reduce the amount of noise generated in the messages file:
scsi(5): Unable to activate fcp priority, ret=0x102
scsi(5): Unable to activate fcp priority, ret=0x102
Also make qla24xx_get_fcp_prio() static.
Signed-off-by: Andrew Vasquez <andrew.vasquez@qlogic.com>
Signed-off-by: Madhuranath Iyengar <Madhu.Iyengar@qlogic.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The respective done() functions are called from process context,
so there's no reason to 'defer' the request.
Signed-off-by: Andrew Vasquez <andrew.vasquez@qlogic.com>
Signed-off-by: Madhuranath Iyengar <Madhu.Iyengar@qlogic.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
To provide a clearer translation of the command-status origin in
relation to the midlayer's standard SCSI nexus.
Signed-off-by: Andrew Vasquez <andrew.vasquez@qlogic.com>
Signed-off-by: Madhuranath Iyengar <Madhu.Iyengar@qlogic.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
There was a bug in setting up type and dmsg for FW
Signed-off-by: Jayamohan Kallickal <jayamohan.kallickal@emulex.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>