mirror of
https://github.com/AuxXxilium/linux_dsm_epyc7002.git
synced 2024-12-17 21:46:43 +07:00
can: peak_usb: fix slab info leak
Fix a small slab info leak due to a failure to clear the command buffer
at allocation.
The first 16 bytes of the command buffer are always sent to the device
in pcan_usb_send_cmd() even though only the first two may have been
initialised in case no argument payload is provided (e.g. when waiting
for a response).
Fixes: bb4785551f
("can: usb: PEAK-System Technik USB adapters driver core")
Cc: stable <stable@vger.kernel.org> # 3.4
Reported-by: syzbot+863724e7128e14b26732@syzkaller.appspotmail.com
Signed-off-by: Johan Hovold <johan@kernel.org>
Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de>
This commit is contained in:
parent
de280f403f
commit
f7a1337f0d
@ -750,7 +750,7 @@ static int peak_usb_create_dev(const struct peak_usb_adapter *peak_usb_adapter,
|
||||
dev = netdev_priv(netdev);
|
||||
|
||||
/* allocate a buffer large enough to send commands */
|
||||
dev->cmd_buf = kmalloc(PCAN_USB_MAX_CMD_LEN, GFP_KERNEL);
|
||||
dev->cmd_buf = kzalloc(PCAN_USB_MAX_CMD_LEN, GFP_KERNEL);
|
||||
if (!dev->cmd_buf) {
|
||||
err = -ENOMEM;
|
||||
goto lbl_free_candev;
|
||||
|
Loading…