rt2x00: configure different txdesc parameters for non HT channel

This is needed when we are concted to non 11n AP.

Signed-off-by: Stanislaw Gruszka <sgruszka@redhat.com>
Signed-off-by: John W. Linville <linville@tuxdriver.com>
This commit is contained in:
Stanislaw Gruszka 2012-04-04 16:15:33 +02:00 committed by John W. Linville
parent 78f9c85035
commit da40f4074f
3 changed files with 24 additions and 8 deletions

View File

@ -692,6 +692,7 @@ enum rt2x00_state_flags {
*/
CONFIG_CHANNEL_HT40,
CONFIG_POWERSAVING,
CONFIG_HT_DISABLED,
/*
* Mark we currently are sequentially reading TX_STA_FIFO register

View File

@ -217,6 +217,11 @@ void rt2x00lib_config(struct rt2x00_dev *rt2x00dev,
libconf.conf = conf;
if (ieee80211_flags & IEEE80211_CONF_CHANGE_CHANNEL) {
if (!conf_is_ht(conf))
set_bit(CONFIG_HT_DISABLED, &rt2x00dev->flags);
else
clear_bit(CONFIG_HT_DISABLED, &rt2x00dev->flags);
if (conf_is_ht40(conf)) {
set_bit(CONFIG_CHANNEL_HT40, &rt2x00dev->flags);
hw_value = rt2x00ht_center_channel(rt2x00dev, conf);

View File

@ -320,14 +320,6 @@ static void rt2x00queue_create_tx_descriptor_ht(struct rt2x00_dev *rt2x00dev,
txdesc->u.ht.wcid = sta_priv->wcid;
}
txdesc->u.ht.ba_size = 7; /* FIXME: What value is needed? */
/*
* Only one STBC stream is supported for now.
*/
if (tx_info->flags & IEEE80211_TX_CTL_STBC)
txdesc->u.ht.stbc = 1;
/*
* If IEEE80211_TX_RC_MCS is set txrate->idx just contains the
* mcs rate to be used
@ -351,6 +343,24 @@ static void rt2x00queue_create_tx_descriptor_ht(struct rt2x00_dev *rt2x00dev,
txdesc->u.ht.mcs |= 0x08;
}
if (test_bit(CONFIG_HT_DISABLED, &rt2x00dev->flags)) {
if (!(tx_info->flags & IEEE80211_TX_CTL_FIRST_FRAGMENT))
txdesc->u.ht.txop = TXOP_SIFS;
else
txdesc->u.ht.txop = TXOP_BACKOFF;
/* Left zero on all other settings. */
return;
}
txdesc->u.ht.ba_size = 7; /* FIXME: What value is needed? */
/*
* Only one STBC stream is supported for now.
*/
if (tx_info->flags & IEEE80211_TX_CTL_STBC)
txdesc->u.ht.stbc = 1;
/*
* This frame is eligible for an AMPDU, however, don't aggregate
* frames that are intended to probe a specific tx rate.