drm/amd/display: do not read link setting if edp not connected
[Why] Previously assume eDP sink present if connector present. Do not need to enforce this restriction. Fix issue where driver attempt to read link setting even though no edp connected. {How] Only read link setting after reading connection status. Signed-off-by: Eric Yang <Eric.Yang2@amd.com> Reviewed-by: Yongqiang Sun <yongqiang.sun@amd.com> Acked-by: Leo Li <sunpeng.li@amd.com> Signed-off-by: Alex Deucher <alexander.deucher@amd.com>
This commit is contained in:
parent
7352193a33
commit
b791f9dc2d
@ -722,13 +722,6 @@ bool dc_link_detect(struct dc_link *link, enum dc_detect_reason reason)
|
||||
return false;
|
||||
}
|
||||
|
||||
if (link->connector_signal == SIGNAL_TYPE_EDP) {
|
||||
/* On detect, we want to make sure current link settings are
|
||||
* up to date, especially if link was powered on by GOP.
|
||||
*/
|
||||
read_edp_current_link_settings_on_detect(link);
|
||||
}
|
||||
|
||||
prev_sink = link->local_sink;
|
||||
if (prev_sink != NULL) {
|
||||
dc_sink_retain(prev_sink);
|
||||
@ -770,6 +763,7 @@ bool dc_link_detect(struct dc_link *link, enum dc_detect_reason reason)
|
||||
}
|
||||
|
||||
case SIGNAL_TYPE_EDP: {
|
||||
read_edp_current_link_settings_on_detect(link);
|
||||
detect_edp_sink_caps(link);
|
||||
sink_caps.transaction_type =
|
||||
DDC_TRANSACTION_TYPE_I2C_OVER_AUX;
|
||||
|