mirror of
https://github.com/AuxXxilium/linux_dsm_epyc7002.git
synced 2024-12-03 12:26:44 +07:00
qlcnic: fix async event handling during diagnostic loopback test
o Handle async events during diagnostic loopback test o Clear loopback mode on failure to receive async events Signed-off-by: Jitendra Kalsaria <jitendra.kalsaria@qlogic.com> Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
parent
58ead415a1
commit
9a05f92bbb
@ -1436,13 +1436,15 @@ int qlcnic_83xx_set_lb_mode(struct qlcnic_adapter *adapter, u8 mode)
|
||||
return status;
|
||||
}
|
||||
|
||||
/* Wait until firmware send IDC Completion AEN */
|
||||
/* Wait for Link and IDC Completion AEN */
|
||||
do {
|
||||
msleep(300);
|
||||
qlcnic_83xx_process_aen(adapter);
|
||||
if (loop++ > QLCNIC_ILB_MAX_RCV_LOOP) {
|
||||
dev_err(&adapter->pdev->dev,
|
||||
"FW did not generate IDC completion AEN\n");
|
||||
clear_bit(QLC_83XX_IDC_COMP_AEN, &ahw->idc.status);
|
||||
qlcnic_83xx_clear_lb_mode(adapter, mode);
|
||||
return -EIO;
|
||||
}
|
||||
} while (test_bit(QLC_83XX_IDC_COMP_AEN, &ahw->idc.status));
|
||||
@ -1474,9 +1476,10 @@ int qlcnic_83xx_clear_lb_mode(struct qlcnic_adapter *adapter, u8 mode)
|
||||
return status;
|
||||
}
|
||||
|
||||
/* Wait until firmware send IDC Completion AEN */
|
||||
/* Wait for Link and IDC Completion AEN */
|
||||
do {
|
||||
msleep(300);
|
||||
qlcnic_83xx_process_aen(adapter);
|
||||
if (loop++ > QLCNIC_ILB_MAX_RCV_LOOP) {
|
||||
dev_err(&adapter->pdev->dev,
|
||||
"Firmware didn't sent IDC completion AEN\n");
|
||||
|