From 867beb60d131f7a5cde88ba375338285fdc6ddb8 Mon Sep 17 00:00:00 2001 From: Lokesh Vutla Date: Thu, 12 Mar 2020 09:52:08 +0530 Subject: [PATCH] pwm: omap-dmtimer: Fix PWM enabling sequence To configure DM timer in PWM mode the following needs to be set in OMAP_TIMER_CTRL_REG using set_pwm callback: - Set toggle mode on PORTIMERPWM output pin - Set trigger on overflow and match on PORTIMERPWM output pin. - Set auto reload This is a one time configuration and needs to be set before the start of the DM timer. But the current driver tries to set the same configuration for every period/duty cycle update, which is not needed. So move the PWM setup before enabling timer and do not update it in pwm_omap_dmtimer_config(). Tested-by: Tony Lindgren Signed-off-by: Lokesh Vutla Signed-off-by: Thierry Reding --- drivers/pwm/pwm-omap-dmtimer.c | 10 +++++----- 1 file changed, 5 insertions(+), 5 deletions(-) diff --git a/drivers/pwm/pwm-omap-dmtimer.c b/drivers/pwm/pwm-omap-dmtimer.c index 92aac6c86b95..85b17b49980b 100644 --- a/drivers/pwm/pwm-omap-dmtimer.c +++ b/drivers/pwm/pwm-omap-dmtimer.c @@ -81,6 +81,11 @@ static int pwm_omap_dmtimer_enable(struct pwm_chip *chip, struct pwm_omap_dmtimer_chip *omap = to_pwm_omap_dmtimer_chip(chip); mutex_lock(&omap->mutex); + omap->pdata->set_pwm(omap->dm_timer, + pwm_get_polarity(pwm) == PWM_POLARITY_INVERSED, + true, OMAP_TIMER_TRIGGER_OVERFLOW_AND_COMPARE, + true); + pwm_omap_dmtimer_start(omap); mutex_unlock(&omap->mutex); @@ -197,11 +202,6 @@ static int pwm_omap_dmtimer_config(struct pwm_chip *chip, dev_dbg(chip->dev, "load value: %#08x (%d), match value: %#08x (%d)\n", load_value, load_value, match_value, match_value); - omap->pdata->set_pwm(omap->dm_timer, - pwm_get_polarity(pwm) == PWM_POLARITY_INVERSED, - true, OMAP_TIMER_TRIGGER_OVERFLOW_AND_COMPARE, - true); - /* If config was called while timer was running it must be reenabled. */ if (timer_active) pwm_omap_dmtimer_start(omap);