iwlwifi: mvm: BT Coex - always set mandatory fields

The firmware always expects the Coex Mode to be set.
Moreover, the firmware expects bit 0 is the valid bits to
be set all the times.
I misunderstood the API and didn't set these bits when
commands are sent to update the paramters of the Coex. As
a result, the firmware understood that the BT Coex was
disabled (Coex mode = 0) and ignored all the updates (valid
bit 0 clear).

Fix that.

Signed-off-by: Emmanuel Grumbach <emmanuel.grumbach@intel.com>
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
This commit is contained in:
Emmanuel Grumbach 2013-10-14 18:52:23 +03:00 committed by Johannes Berg
parent 8a87bdddf9
commit 7352cac0a3
2 changed files with 11 additions and 3 deletions

View File

@ -471,11 +471,13 @@ static int iwl_mvm_bt_udpate_ctrl_kill_msk(struct iwl_mvm *mvm,
if (!bt_cmd)
return -ENOMEM;
cmd.data[0] = bt_cmd;
bt_cmd->flags = cpu_to_le32(BT_COEX_NW);
bt_cmd->kill_ack_msk = cpu_to_le32(iwl_bt_ack_kill_msk[bt_kill_msk]);
bt_cmd->kill_cts_msk = cpu_to_le32(iwl_bt_cts_kill_msk[bt_kill_msk]);
bt_cmd->valid_bit_msk =
cpu_to_le32(BT_VALID_KILL_ACK | BT_VALID_KILL_CTS);
bt_cmd->valid_bit_msk |= cpu_to_le32(BT_VALID_ENABLE |
BT_VALID_KILL_ACK |
BT_VALID_KILL_CTS);
IWL_DEBUG_COEX(mvm, "ACK Kill msk = 0x%08x, CTS Kill msk = 0x%08x\n",
iwl_bt_ack_kill_msk[bt_kill_msk],
@ -519,8 +521,10 @@ static int iwl_mvm_bt_coex_reduced_txp(struct iwl_mvm *mvm, u8 sta_id,
if (!bt_cmd)
return -ENOMEM;
cmd.data[0] = bt_cmd;
bt_cmd->flags = cpu_to_le32(BT_COEX_NW);
bt_cmd->valid_bit_msk = cpu_to_le32(BT_VALID_REDUCED_TX_POWER),
bt_cmd->valid_bit_msk =
cpu_to_le32(BT_VALID_ENABLE | BT_VALID_REDUCED_TX_POWER);
bt_cmd->bt_reduced_tx_power = sta_id;
if (enable)

View File

@ -82,6 +82,8 @@
* @BT_USE_DEFAULTS:
* @BT_SYNC_2_BT_DISABLE:
* @BT_COEX_CORUNNING_TBL_EN:
*
* The COEX_MODE must be set for each command. Even if it is not changed.
*/
enum iwl_bt_coex_flags {
BT_CH_PRIMARY_EN = BIT(0),
@ -103,6 +105,8 @@ enum iwl_bt_coex_flags {
/*
* indicates what has changed in the BT_COEX command.
* BT_VALID_ENABLE must be set for each command. Commands without this bit will
* discarded by the firmware
*/
enum iwl_bt_coex_valid_bit_msk {
BT_VALID_ENABLE = BIT(0),