i40e: increase AQ work limit

With 64 VFs, we can easily overwhelm the AQ on the PF if we have too low
a limit on the number of AQ requests. This leads to ARQ overflow errors,
and occasionally VFs that fail to initialize.

Since we really only hit this condition on initial VF driver load, the
requests that we process are lightweight, so this extra work doesn't
cause problems for the PF driver.

Change-ID: I620221520d8af987df6ace9ba938ffaf22107681
Signed-off-by: Mitch Williams <mitch.a.williams@intel.com>
Tested-by: Andrew Bowers <andrewx.bowers@intel.com>
Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>
This commit is contained in:
Mitch Williams 2015-09-28 14:12:43 -04:00 committed by Jeff Kirsher
parent 3f7e5c330e
commit 628f096d8d

View File

@ -93,7 +93,7 @@
#endif /* I40E_FCOE */
#define I40E_MAX_AQ_BUF_SIZE 4096
#define I40E_AQ_LEN 256
#define I40E_AQ_WORK_LIMIT 32
#define I40E_AQ_WORK_LIMIT 66 /* max number of VFs + a little */
#define I40E_MAX_USER_PRIORITY 8
#define I40E_DEFAULT_MSG_ENABLE 4
#define I40E_QUEUE_WAIT_RETRY_LIMIT 10