MIPS: ralink: Fix invalid tick count

The current code adds the delta twice, which is obviously wrong.

Signed-off-by: John Crispin <blogic@openwrt.org>
Cc: linux-mips@linux-mips.org
Patchwork: https://patchwork.linux-mips.org/patch/11443/
Signed-off-by: Ralf Baechle <ralf@linux-mips.org>
This commit is contained in:
John Crispin 2015-11-04 11:50:10 +01:00 committed by Ralf Baechle
parent 73afa6c420
commit 37bcc03f97

View File

@ -48,7 +48,7 @@ static int systick_next_event(unsigned long delta,
sdev = container_of(evt, struct systick_device, dev);
count = ioread32(sdev->membase + SYSTICK_COUNT);
count = (count + delta) % SYSTICK_FREQ;
iowrite32(count + delta, sdev->membase + SYSTICK_COMPARE);
iowrite32(count, sdev->membase + SYSTICK_COMPARE);
return 0;
}