HID: wacom: fix proximity tool release
Don't zero the current tool before reporting its release to the input subsystem. Signed-off-by: Aristeu Rozanski <aris@redhat.com> Tested-by: Przemo Firszt <przemo@firszt.eu> Signed-off-by: Jiri Kosina <jkosina@suse.cz>
This commit is contained in:
parent
217c8b2b19
commit
32db737fb2
@ -322,10 +322,10 @@ static void wacom_i4_parse_pen_report(struct wacom_data *wdata,
|
||||
|
||||
switch (data[1]) {
|
||||
case 0x80: /* Out of proximity report */
|
||||
wdata->tool = 0;
|
||||
input_report_key(input, BTN_TOUCH, 0);
|
||||
input_report_abs(input, ABS_PRESSURE, 0);
|
||||
input_report_key(input, wdata->tool, 0);
|
||||
wdata->tool = 0;
|
||||
input_sync(input);
|
||||
break;
|
||||
case 0xC2: /* Tool report */
|
||||
|
Loading…