drm/edid: Return DispID length from drm_find_displayid_extension()

As with the byte offset (idx) drm_find_displayid_extension() is
the only one who actually knows how much data the resulting DispID
block can contain. So return the length from therein instead of
assuming it's the EDID block length all over.

Signed-off-by: Ville Syrjälä <ville.syrjala@linux.intel.com>
Link: https://patchwork.freedesktop.org/patch/msgid/20200313162054.16009-5-ville.syrjala@linux.intel.com
Reviewed-by: Alex Deucher <alexander.deucher@amd.com>
This commit is contained in:
Ville Syrjälä 2020-03-13 18:20:49 +02:00
parent 3688118404
commit 23b03867a2

View File

@ -3212,13 +3212,15 @@ static u8 *drm_find_edid_extension(const struct edid *edid, int ext_id)
}
static u8 *drm_find_displayid_extension(const struct edid *edid, int *idx)
static u8 *drm_find_displayid_extension(const struct edid *edid,
int *length, int *idx)
{
u8 *displayid = drm_find_edid_extension(edid, DISPLAYID_EXT);
if (!displayid)
return NULL;
*length = EDID_LENGTH;
*idx = 1;
return displayid;
@ -3227,8 +3229,7 @@ static u8 *drm_find_displayid_extension(const struct edid *edid, int *idx)
static u8 *drm_find_cea_extension(const struct edid *edid)
{
int ret;
int idx;
int length = EDID_LENGTH;
int length, idx;
struct displayid_block *block;
u8 *cea;
u8 *displayid;
@ -3239,7 +3240,7 @@ static u8 *drm_find_cea_extension(const struct edid *edid)
return cea;
/* CEA blocks can also be found embedded in a DisplayID block */
displayid = drm_find_displayid_extension(edid, &idx);
displayid = drm_find_displayid_extension(edid, &length, &idx);
if (!displayid)
return NULL;
@ -5188,12 +5189,11 @@ static int add_displayid_detailed_modes(struct drm_connector *connector,
{
u8 *displayid;
int ret;
int idx;
int length = EDID_LENGTH;
int length, idx;
struct displayid_block *block;
int num_modes = 0;
displayid = drm_find_displayid_extension(edid, &idx);
displayid = drm_find_displayid_extension(edid, &length, &idx);
if (!displayid)
return 0;
@ -5881,17 +5881,17 @@ static void drm_get_displayid(struct drm_connector *connector,
struct edid *edid)
{
void *displayid = NULL;
int idx;
int length, idx;
int ret;
connector->has_tile = false;
displayid = drm_find_displayid_extension(edid, &idx);
displayid = drm_find_displayid_extension(edid, &length, &idx);
if (!displayid) {
/* drop reference to any tile group we had */
goto out_drop_ref;
}
ret = drm_parse_display_id(connector, displayid, EDID_LENGTH, idx);
ret = drm_parse_display_id(connector, displayid, length, idx);
if (ret < 0)
goto out_drop_ref;
if (!connector->has_tile)