thermal: armada: Add generic infrastructure to handle the sensor
In order to support similar SoC where the sensor value and valid bit can have different shifts and/or mask, we add such fields to the per-variant structure, instead of having the values hardcoded. Acked-by: Jason Cooper <jason@lakedaemon.net> Signed-off-by: Ezequiel Garcia <ezequiel.garcia@free-electrons.com> Signed-off-by: Zhang Rui <rui.zhang@intel.com>
This commit is contained in:
parent
9484bc62ca
commit
1fcacca40a
@ -24,10 +24,7 @@
|
||||
#include <linux/of_device.h>
|
||||
#include <linux/thermal.h>
|
||||
|
||||
#define THERMAL_VALID_OFFSET 9
|
||||
#define THERMAL_VALID_MASK 0x1
|
||||
#define THERMAL_TEMP_OFFSET 10
|
||||
#define THERMAL_TEMP_MASK 0x1ff
|
||||
|
||||
/* Thermal Manager Control and Status Register */
|
||||
#define PMU_TDC0_SW_RST_MASK (0x1 << 1)
|
||||
@ -58,6 +55,11 @@ struct armada_thermal_data {
|
||||
unsigned long coef_b;
|
||||
unsigned long coef_m;
|
||||
unsigned long coef_div;
|
||||
|
||||
/* Register shift and mask to access the sensor temperature */
|
||||
unsigned int temp_shift;
|
||||
unsigned int temp_mask;
|
||||
unsigned int is_valid_shift;
|
||||
};
|
||||
|
||||
static void armadaxp_init_sensor(struct armada_thermal_priv *priv)
|
||||
@ -108,7 +110,7 @@ static bool armada_is_valid(struct armada_thermal_priv *priv)
|
||||
{
|
||||
unsigned long reg = readl_relaxed(priv->sensor);
|
||||
|
||||
return (reg >> THERMAL_VALID_OFFSET) & THERMAL_VALID_MASK;
|
||||
return (reg >> priv->data->is_valid_shift) & THERMAL_VALID_MASK;
|
||||
}
|
||||
|
||||
static int armada_get_temp(struct thermal_zone_device *thermal,
|
||||
@ -126,7 +128,7 @@ static int armada_get_temp(struct thermal_zone_device *thermal,
|
||||
}
|
||||
|
||||
reg = readl_relaxed(priv->sensor);
|
||||
reg = (reg >> THERMAL_TEMP_OFFSET) & THERMAL_TEMP_MASK;
|
||||
reg = (reg >> priv->data->temp_shift) & priv->data->temp_mask;
|
||||
|
||||
/* Get formula coeficients */
|
||||
b = priv->data->coef_b;
|
||||
@ -143,6 +145,8 @@ static struct thermal_zone_device_ops ops = {
|
||||
|
||||
static const struct armada_thermal_data armadaxp_data = {
|
||||
.init_sensor = armadaxp_init_sensor,
|
||||
.temp_shift = 10,
|
||||
.temp_mask = 0x1ff,
|
||||
.coef_b = 3153000000UL,
|
||||
.coef_m = 10000000UL,
|
||||
.coef_div = 13825,
|
||||
@ -151,6 +155,9 @@ static const struct armada_thermal_data armadaxp_data = {
|
||||
static const struct armada_thermal_data armada370_data = {
|
||||
.is_valid = armada_is_valid,
|
||||
.init_sensor = armada370_init_sensor,
|
||||
.is_valid_shift = 9,
|
||||
.temp_shift = 10,
|
||||
.temp_mask = 0x1ff,
|
||||
.coef_b = 3153000000UL,
|
||||
.coef_m = 10000000UL,
|
||||
.coef_div = 13825,
|
||||
|