regulator: dt bindings: add BD71847 device-tree binding documentation

Add ROHM BD71847 Power Management IC regulator binding information to
device-tree binding documents.

Signed-off-by: Matti Vaittinen <matti.vaittinen@fi.rohmeurope.com>
Reviewed-by: Rob Herring <robh@kernel.org>
Signed-off-by: Mark Brown <broonie@kernel.org>
This commit is contained in:
Matti Vaittinen 2018-09-14 11:30:06 +03:00 committed by Mark Brown
parent 494edd266b
commit 12fc309a95
No known key found for this signature in database
GPG Key ID: 24D68B725D5487D0

View File

@ -1,7 +1,9 @@
ROHM BD71837 Power Management Integrated Circuit (PMIC) regulator bindings
ROHM BD71837 and BD71847 Power Management Integrated Circuit regulator bindings
Required properties:
- regulator-name: should be "buck1", ..., "buck8" and "ldo1", ..., "ldo7"
- regulator-name: should be "buck1", ..., "buck8" and "ldo1", ..., "ldo7" for
BD71837. For BD71847 names should be "buck1", ..., "buck6"
and "ldo1", ..., "ldo6"
List of regulators provided by this controller. BD71837 regulators node
should be sub node of the BD71837 MFD node. See BD71837 MFD bindings at
@ -16,10 +18,14 @@ disabled by driver at startup. LDO5 and LDO6 are supplied by those and
if they are disabled at startup the voltage monitoring for LDO5/LDO6 will
cause PMIC to reset.
The valid names for regulator nodes are:
The valid names for BD71837 regulator nodes are:
BUCK1, BUCK2, BUCK3, BUCK4, BUCK5, BUCK6, BUCK7, BUCK8
LDO1, LDO2, LDO3, LDO4, LDO5, LDO6, LDO7
The valid names for BD71847 regulator nodes are:
BUCK1, BUCK2, BUCK3, BUCK4, BUCK5, BUCK6
LDO1, LDO2, LDO3, LDO4, LDO5, LDO6
Optional properties:
- Any optional property defined in bindings/regulator/regulator.txt