regulator: dt bindings: add BD71847 device-tree binding documentation
Add ROHM BD71847 Power Management IC regulator binding information to device-tree binding documents. Signed-off-by: Matti Vaittinen <matti.vaittinen@fi.rohmeurope.com> Reviewed-by: Rob Herring <robh@kernel.org> Signed-off-by: Mark Brown <broonie@kernel.org>
This commit is contained in:
parent
494edd266b
commit
12fc309a95
@ -1,7 +1,9 @@
|
||||
ROHM BD71837 Power Management Integrated Circuit (PMIC) regulator bindings
|
||||
ROHM BD71837 and BD71847 Power Management Integrated Circuit regulator bindings
|
||||
|
||||
Required properties:
|
||||
- regulator-name: should be "buck1", ..., "buck8" and "ldo1", ..., "ldo7"
|
||||
- regulator-name: should be "buck1", ..., "buck8" and "ldo1", ..., "ldo7" for
|
||||
BD71837. For BD71847 names should be "buck1", ..., "buck6"
|
||||
and "ldo1", ..., "ldo6"
|
||||
|
||||
List of regulators provided by this controller. BD71837 regulators node
|
||||
should be sub node of the BD71837 MFD node. See BD71837 MFD bindings at
|
||||
@ -16,10 +18,14 @@ disabled by driver at startup. LDO5 and LDO6 are supplied by those and
|
||||
if they are disabled at startup the voltage monitoring for LDO5/LDO6 will
|
||||
cause PMIC to reset.
|
||||
|
||||
The valid names for regulator nodes are:
|
||||
The valid names for BD71837 regulator nodes are:
|
||||
BUCK1, BUCK2, BUCK3, BUCK4, BUCK5, BUCK6, BUCK7, BUCK8
|
||||
LDO1, LDO2, LDO3, LDO4, LDO5, LDO6, LDO7
|
||||
|
||||
The valid names for BD71847 regulator nodes are:
|
||||
BUCK1, BUCK2, BUCK3, BUCK4, BUCK5, BUCK6
|
||||
LDO1, LDO2, LDO3, LDO4, LDO5, LDO6
|
||||
|
||||
Optional properties:
|
||||
- Any optional property defined in bindings/regulator/regulator.txt
|
||||
|
||||
|