linux_dsm_epyc7002/net/tipc/addr.c

124 lines
3.7 KiB
C
Raw Normal View History

/*
* net/tipc/addr.c: TIPC address utility routines
*
* Copyright (c) 2000-2006, 2018, Ericsson AB
* Copyright (c) 2004-2005, 2010-2011, Wind River Systems
* All rights reserved.
*
* Redistribution and use in source and binary forms, with or without
* modification, are permitted provided that the following conditions are met:
*
* 1. Redistributions of source code must retain the above copyright
* notice, this list of conditions and the following disclaimer.
* 2. Redistributions in binary form must reproduce the above copyright
* notice, this list of conditions and the following disclaimer in the
* documentation and/or other materials provided with the distribution.
* 3. Neither the names of the copyright holders nor the names of its
* contributors may be used to endorse or promote products derived from
* this software without specific prior written permission.
*
* Alternatively, this software may be distributed under the terms of the
* GNU General Public License ("GPL") version 2 as published by the Free
* Software Foundation.
*
* THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS"
* AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
* IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
* ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR CONTRIBUTORS BE
* LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
* CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
* SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
* INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
* CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
* ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
* POSSIBILITY OF SUCH DAMAGE.
*/
#include "addr.h"
#include "core.h"
2018-03-23 02:42:48 +07:00
bool tipc_in_scope(bool legacy_format, u32 domain, u32 addr)
{
if (!domain || (domain == addr))
2018-03-23 02:42:48 +07:00
return true;
if (!legacy_format)
return false;
if (domain == tipc_cluster_mask(addr)) /* domain <Z.C.0> */
2018-03-23 02:42:48 +07:00
return true;
if (domain == (addr & TIPC_ZONE_CLUSTER_MASK)) /* domain <Z.C.0> */
return true;
tipc: remove restrictions on node address values Nominally, TIPC organizes network nodes into a three-level network hierarchy consisting of the levels 'zone', 'cluster' and 'node'. This hierarchy is reflected in the node address format, - it is sub-divided into an 8-bit zone id, and 12 bit cluster id, and a 12-bit node id. However, the 'zone' and 'cluster' levels have in reality never been fully implemented,and never will be. The result of this has been that the first 20 bits the node identity structure have been wasted, and the usable node identity range within a cluster has been limited to 12 bits. This is starting to become a problem. In the following commits, we will need to be able to connect between nodes which are using the whole 32-bit value space of the node address. We therefore remove the restrictions on which values can be assigned to node identity, -it is from now on only a 32-bit integer with no assumed internal structure. Isolation between clusters is now achieved only by setting different values for the 'network id' field used during neighbor discovery, in practice leading to the latter becoming the new cluster identity. The rules for accepting discovery requests/responses from neighboring nodes now become: - If the user is using legacy address format on both peers, reception of discovery messages is subject to the legacy lookup domain check in addition to the cluster id check. - Otherwise, the discovery request/response is always accepted, provided both peers have the same network id. This secures backwards compatibility for users who have been using zone or cluster identities as cluster separators, instead of the intended 'network id'. Acked-by: Ying Xue <ying.xue@windriver.com> Signed-off-by: Jon Maloy <jon.maloy@ericsson.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2018-03-23 02:42:47 +07:00
if (domain == (addr & TIPC_ZONE_MASK)) /* domain <Z.0.0> */
2018-03-23 02:42:48 +07:00
return true;
return false;
}
void tipc_set_node_id(struct net *net, u8 *id)
{
struct tipc_net *tn = tipc_net(net);
u32 *tmp = (u32 *)id;
memcpy(tn->node_id, id, NODE_ID_LEN);
tipc_nodeid2string(tn->node_id_string, id);
tipc: handle collisions of 32-bit node address hash values When a 32-bit node address is generated from a 128-bit identifier, there is a risk of collisions which must be discovered and handled. We do this as follows: - We don't apply the generated address immediately to the node, but do instead initiate a 1 sec trial period to allow other cluster members to discover and handle such collisions. - During the trial period the node periodically sends out a new type of message, DSC_TRIAL_MSG, using broadcast or emulated broadcast, to all the other nodes in the cluster. - When a node is receiving such a message, it must check that the presented 32-bit identifier either is unused, or was used by the very same peer in a previous session. In both cases it accepts the request by not responding to it. - If it finds that the same node has been up before using a different address, it responds with a DSC_TRIAL_FAIL_MSG containing that address. - If it finds that the address has already been taken by some other node, it generates a new, unused address and returns it to the requester. - During the trial period the requesting node must always be prepared to accept a failure message, i.e., a message where a peer suggests a different (or equal) address to the one tried. In those cases it must apply the suggested value as trial address and restart the trial period. This algorithm ensures that in the vast majority of cases a node will have the same address before and after a reboot. If a legacy user configures the address explicitly, there will be no trial period and messages, so this protocol addition is completely backwards compatible. Acked-by: Ying Xue <ying.xue@windriver.com> Signed-off-by: Jon Maloy <jon.maloy@ericsson.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2018-03-23 02:42:51 +07:00
tn->trial_addr = tmp[0] ^ tmp[1] ^ tmp[2] ^ tmp[3];
pr_info("Own node identity %s, cluster identity %u\n",
tipc_own_id_string(net), tn->net_id);
}
void tipc_set_node_addr(struct net *net, u32 addr)
{
struct tipc_net *tn = tipc_net(net);
u8 node_id[NODE_ID_LEN] = {0,};
tn->node_addr = addr;
if (!tipc_own_id(net)) {
sprintf(node_id, "%x", addr);
tipc_set_node_id(net, node_id);
}
tipc: handle collisions of 32-bit node address hash values When a 32-bit node address is generated from a 128-bit identifier, there is a risk of collisions which must be discovered and handled. We do this as follows: - We don't apply the generated address immediately to the node, but do instead initiate a 1 sec trial period to allow other cluster members to discover and handle such collisions. - During the trial period the node periodically sends out a new type of message, DSC_TRIAL_MSG, using broadcast or emulated broadcast, to all the other nodes in the cluster. - When a node is receiving such a message, it must check that the presented 32-bit identifier either is unused, or was used by the very same peer in a previous session. In both cases it accepts the request by not responding to it. - If it finds that the same node has been up before using a different address, it responds with a DSC_TRIAL_FAIL_MSG containing that address. - If it finds that the address has already been taken by some other node, it generates a new, unused address and returns it to the requester. - During the trial period the requesting node must always be prepared to accept a failure message, i.e., a message where a peer suggests a different (or equal) address to the one tried. In those cases it must apply the suggested value as trial address and restart the trial period. This algorithm ensures that in the vast majority of cases a node will have the same address before and after a reboot. If a legacy user configures the address explicitly, there will be no trial period and messages, so this protocol addition is completely backwards compatible. Acked-by: Ying Xue <ying.xue@windriver.com> Signed-off-by: Jon Maloy <jon.maloy@ericsson.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2018-03-23 02:42:51 +07:00
tn->trial_addr = addr;
pr_info("32-bit node address hash set to %x\n", addr);
}
char *tipc_nodeid2string(char *str, u8 *id)
{
int i;
u8 c;
/* Already a string ? */
for (i = 0; i < NODE_ID_LEN; i++) {
c = id[i];
if (c >= '0' && c <= '9')
continue;
if (c >= 'A' && c <= 'Z')
continue;
if (c >= 'a' && c <= 'z')
continue;
if (c == '.')
continue;
if (c == ':')
continue;
if (c == '_')
continue;
if (c == '-')
continue;
if (c == '@')
continue;
if (c != 0)
break;
}
if (i == NODE_ID_LEN) {
memcpy(str, id, NODE_ID_LEN);
str[NODE_ID_LEN] = 0;
return str;
}
/* Translate to hex string */
for (i = 0; i < NODE_ID_LEN; i++)
sprintf(&str[2 * i], "%02x", id[i]);
/* Strip off trailing zeroes */
for (i = NODE_ID_STR_LEN - 2; str[i] == '0'; i--)
str[i] = 0;
return str;
}