2010-05-28 00:58:56 +07:00
|
|
|
Kernel driver tmp102
|
|
|
|
====================
|
|
|
|
|
|
|
|
Supported chips:
|
2019-04-17 16:46:28 +07:00
|
|
|
|
2010-05-28 00:58:56 +07:00
|
|
|
* Texas Instruments TMP102
|
2019-04-17 16:46:28 +07:00
|
|
|
|
2010-05-28 00:58:56 +07:00
|
|
|
Prefix: 'tmp102'
|
2019-04-17 16:46:28 +07:00
|
|
|
|
2010-05-28 00:58:57 +07:00
|
|
|
Addresses scanned: none
|
2019-04-17 16:46:28 +07:00
|
|
|
|
2010-05-28 00:58:56 +07:00
|
|
|
Datasheet: http://focus.ti.com/docs/prod/folders/print/tmp102.html
|
|
|
|
|
|
|
|
Author:
|
2019-04-17 16:46:28 +07:00
|
|
|
|
2010-05-28 00:58:56 +07:00
|
|
|
Steven King <sfking@fdwdc.com>
|
|
|
|
|
|
|
|
Description
|
|
|
|
-----------
|
|
|
|
|
|
|
|
The Texas Instruments TMP102 implements one temperature sensor. Limits can be
|
|
|
|
set through the Overtemperature Shutdown register and Hysteresis register. The
|
2010-05-28 00:58:57 +07:00
|
|
|
sensor is accurate to 0.5 degree over the range of -25 to +85 C, and to 1.0
|
|
|
|
degree from -40 to +125 C. Resolution of the sensor is 0.0625 degree. The
|
2010-05-28 00:58:56 +07:00
|
|
|
operating temperature has a minimum of -55 C and a maximum of +150 C.
|
|
|
|
|
|
|
|
The TMP102 has a programmable update rate that can select between 8, 4, 1, and
|
|
|
|
0.5 Hz. (Currently the driver only supports the default of 4 Hz).
|
|
|
|
|
|
|
|
The driver provides the common sysfs-interface for temperatures (see
|
2019-04-17 16:46:29 +07:00
|
|
|
Documentation/hwmon/sysfs-interface.rst under Temperatures).
|