* Xilinx SDFEC(16nm) IP *
The Soft Decision Forward Error Correction (SDFEC) Engine is a Hard IP block
which provides high-throughput LDPC and Turbo Code implementations.
The LDPC decode & encode functionality is capable of covering a range of
customer specified Quasi-cyclic (QC) codes. The Turbo decode functionality
principally covers codes used by LTE. The FEC Engine offers significant
power and area savings versus implementations done in the FPGA fabric.
Required properties:
- compatible: Must be "xlnx,sd-fec-1.1"
- clock-names : List of input clock names from the following:
- "core_clk", Main processing clock for processing core (required)
- "s_axi_aclk", AXI4-Lite memory-mapped slave interface clock (required)
- "s_axis_din_aclk", DIN AXI4-Stream Slave interface clock (optional)
- "s_axis_din_words-aclk", DIN_WORDS AXI4-Stream Slave interface clock (optional)
- "s_axis_ctrl_aclk", Control input AXI4-Stream Slave interface clock (optional)
- "m_axis_dout_aclk", DOUT AXI4-Stream Master interface clock (optional)
- "m_axis_dout_words_aclk", DOUT_WORDS AXI4-Stream Master interface clock (optional)
- "m_axis_status_aclk", Status output AXI4-Stream Master interface clock (optional)
- clocks : Clock phandles (see clock_bindings.txt for details).
- reg: Should contain Xilinx SDFEC 16nm Hardened IP block registers
location and length.
- xlnx,sdfec-code : Should contain "ldpc" or "turbo" to describe the codes
being used.
- xlnx,sdfec-din-words : A value 0 indicates that the DIN_WORDS interface is
driven with a fixed value and is not present on the device, a value of 1
configures the DIN_WORDS to be block based, while a value of 2 configures the
DIN_WORDS input to be supplied for each AXI transaction.
- xlnx,sdfec-din-width : Configures the DIN AXI stream where a value of 1
configures a width of "1x128b", 2 a width of "2x128b" and 4 configures a width
of "4x128b".
- xlnx,sdfec-dout-words : A value 0 indicates that the DOUT_WORDS interface is
driven with a fixed value and is not present on the device, a value of 1
configures the DOUT_WORDS to be block based, while a value of 2 configures the
DOUT_WORDS input to be supplied for each AXI transaction.
- xlnx,sdfec-dout-width : Configures the DOUT AXI stream where a value of 1
configures a width of "1x128b", 2 a width of "2x128b" and 4 configures a width
of "4x128b".
Optional properties:
- interrupts: should contain SDFEC interrupt number
Example
---------------------------------------
sd_fec_0: sd-fec@a0040000 {
compatible = "xlnx,sd-fec-1.1";
clock-names = "core_clk","s_axi_aclk","s_axis_ctrl_aclk","s_axis_din_aclk","m_axis_status_aclk","m_axis_dout_aclk";
clocks = <&misc_clk_2>,<&misc_clk_0>,<&misc_clk_1>,<&misc_clk_1>,<&misc_clk_1>, <&misc_clk_1>;
reg = <0x0 0xa0040000 0x0 0x40000>;
interrupt-parent = <&axi_intc>;
interrupts = <1 0>;
xlnx,sdfec-code = "ldpc";
xlnx,sdfec-din-words = <0>;
xlnx,sdfec-din-width = <2>;
xlnx,sdfec-dout-words = <0>;
xlnx,sdfec-dout-width = <1>;
};