linux_dsm_epyc7002/arch/s390/include/asm/topology.h

61 lines
1.5 KiB
C
Raw Normal View History

#ifndef _ASM_S390_TOPOLOGY_H
#define _ASM_S390_TOPOLOGY_H
#include <linux/cpumask.h>
struct sysinfo_15_1_x;
struct cpu;
#ifdef CONFIG_SCHED_BOOK
struct cpu_topology_s390 {
unsigned short core_id;
unsigned short socket_id;
unsigned short book_id;
cpumask_t core_mask;
cpumask_t book_mask;
};
extern struct cpu_topology_s390 cpu_topology[NR_CPUS];
#define topology_physical_package_id(cpu) (cpu_topology[cpu].socket_id)
#define topology_core_id(cpu) (cpu_topology[cpu].core_id)
#define topology_core_cpumask(cpu) (&cpu_topology[cpu].core_mask)
#define topology_book_id(cpu) (cpu_topology[cpu].book_id)
#define topology_book_cpumask(cpu) (&cpu_topology[cpu].book_mask)
#define mc_capable() 1
int topology_cpu_init(struct cpu *);
[S390] Vertical cpu management. If vertical cpu polarization is active then the hypervisor will dispatch certain cpus for a longer time than other cpus for maximum performance. For example if a guest would have three virtual cpus, each of them with a share of 33 percent, then in case of vertical cpu polarization all of the processing time would be combined to a single cpu which would run all the time, while the other two cpus would get nearly no cpu time. There are three different types of vertical cpus: high, medium and low. Low cpus hardly get any real cpu time, while high cpus get a full real cpu. Medium cpus get something in between. In order to switch between the two possible modes (default is horizontal) a 0 for horizontal polarization or a 1 for vertical polarization must be written to the dispatching sysfs attribute: /sys/devices/system/cpu/dispatching The polarization of each single cpu can be figured out by the polarization sysfs attribute of each cpu: /sys/devices/system/cpu/cpuX/polarization horizontal, vertical:high, vertical:medium, vertical:low or unknown. When switching polarization the polarization attribute may contain the value unknown until the configuration change is done and the kernel has figured out the new polarization of each cpu. Note that running a system with different types of vertical cpus may result in significant performance regressions. If possible only one type of vertical cpus should be used. All other cpus should be offlined. Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com> Signed-off-by: Heiko Carstens <heiko.carstens@de.ibm.com>
2008-04-17 12:46:13 +07:00
int topology_set_cpu_management(int fc);
void topology_schedule_update(void);
void store_topology(struct sysinfo_15_1_x *info);
void topology_expect_change(void);
const struct cpumask *cpu_coregroup_mask(int cpu);
[S390] Vertical cpu management. If vertical cpu polarization is active then the hypervisor will dispatch certain cpus for a longer time than other cpus for maximum performance. For example if a guest would have three virtual cpus, each of them with a share of 33 percent, then in case of vertical cpu polarization all of the processing time would be combined to a single cpu which would run all the time, while the other two cpus would get nearly no cpu time. There are three different types of vertical cpus: high, medium and low. Low cpus hardly get any real cpu time, while high cpus get a full real cpu. Medium cpus get something in between. In order to switch between the two possible modes (default is horizontal) a 0 for horizontal polarization or a 1 for vertical polarization must be written to the dispatching sysfs attribute: /sys/devices/system/cpu/dispatching The polarization of each single cpu can be figured out by the polarization sysfs attribute of each cpu: /sys/devices/system/cpu/cpuX/polarization horizontal, vertical:high, vertical:medium, vertical:low or unknown. When switching polarization the polarization attribute may contain the value unknown until the configuration change is done and the kernel has figured out the new polarization of each cpu. Note that running a system with different types of vertical cpus may result in significant performance regressions. If possible only one type of vertical cpus should be used. All other cpus should be offlined. Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com> Signed-off-by: Heiko Carstens <heiko.carstens@de.ibm.com>
2008-04-17 12:46:13 +07:00
#else /* CONFIG_SCHED_BOOK */
static inline void topology_schedule_update(void) { }
static inline int topology_cpu_init(struct cpu *cpu) { return 0; }
static inline void topology_expect_change(void) { }
#endif /* CONFIG_SCHED_BOOK */
#define POLARIZATION_UNKNOWN (-1)
[S390] Vertical cpu management. If vertical cpu polarization is active then the hypervisor will dispatch certain cpus for a longer time than other cpus for maximum performance. For example if a guest would have three virtual cpus, each of them with a share of 33 percent, then in case of vertical cpu polarization all of the processing time would be combined to a single cpu which would run all the time, while the other two cpus would get nearly no cpu time. There are three different types of vertical cpus: high, medium and low. Low cpus hardly get any real cpu time, while high cpus get a full real cpu. Medium cpus get something in between. In order to switch between the two possible modes (default is horizontal) a 0 for horizontal polarization or a 1 for vertical polarization must be written to the dispatching sysfs attribute: /sys/devices/system/cpu/dispatching The polarization of each single cpu can be figured out by the polarization sysfs attribute of each cpu: /sys/devices/system/cpu/cpuX/polarization horizontal, vertical:high, vertical:medium, vertical:low or unknown. When switching polarization the polarization attribute may contain the value unknown until the configuration change is done and the kernel has figured out the new polarization of each cpu. Note that running a system with different types of vertical cpus may result in significant performance regressions. If possible only one type of vertical cpus should be used. All other cpus should be offlined. Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com> Signed-off-by: Heiko Carstens <heiko.carstens@de.ibm.com>
2008-04-17 12:46:13 +07:00
#define POLARIZATION_HRZ (0)
#define POLARIZATION_VL (1)
#define POLARIZATION_VM (2)
#define POLARIZATION_VH (3)
#ifdef CONFIG_SCHED_BOOK
void s390_init_cpu_topology(void);
#else
static inline void s390_init_cpu_topology(void)
{
};
#endif
#include <asm-generic/topology.h>
#endif /* _ASM_S390_TOPOLOGY_H */