mirror of
https://github.com/AuxXxilium/eudev.git
synced 2024-12-14 10:37:11 +07:00
man: finish service man page
This commit is contained in:
parent
16c42ce173
commit
0d624a785a
@ -62,140 +62,437 @@
|
|||||||
specific to this unit type. See
|
specific to this unit type. See
|
||||||
<citerefentry><refentrytitle>systemd.unit</refentrytitle><manvolnum>5</manvolnum></citerefentry>
|
<citerefentry><refentrytitle>systemd.unit</refentrytitle><manvolnum>5</manvolnum></citerefentry>
|
||||||
for the common options of all unit configuration
|
for the common options of all unit configuration
|
||||||
files.</para>
|
files. The common configuration items are configured
|
||||||
|
in the generic [Unit] and [Install] sections. The
|
||||||
|
service specific configuration options are configured
|
||||||
|
in the [Service] section.</para>
|
||||||
|
|
||||||
|
<para>Additional options are listed in <citerefentry><refentrytitle>systemd.exec</refentrytitle><manvolnum>5</manvolnum></citerefentry>.</para>
|
||||||
</refsect1>
|
</refsect1>
|
||||||
|
|
||||||
<refsect1>
|
<refsect1>
|
||||||
<title>Options</title>
|
<title>Options</title>
|
||||||
|
|
||||||
|
<para>Service files must include a [Service] section,
|
||||||
|
which carries information about the service and the
|
||||||
|
process it supervises. A number of options that may be
|
||||||
|
used in this section are shared with other unit
|
||||||
|
types. These options are documented in
|
||||||
|
<citerefentry><refentrytitle>systemd.exec</refentrytitle><manvolnum>5</manvolnum></citerefentry>. The
|
||||||
|
options specific to the [Service] section of service
|
||||||
|
units are the following:</para>
|
||||||
|
|
||||||
<variablelist>
|
<variablelist>
|
||||||
<varlistentry>
|
<varlistentry>
|
||||||
<term><varname>Type=</varname></term>
|
<term><varname>Type=</varname></term>
|
||||||
<listitem>
|
|
||||||
<para>One of
|
|
||||||
<literal>forking</literal>,
|
|
||||||
<literal>simple</literal>,
|
|
||||||
<literal>finish</literal>,
|
|
||||||
<literal>dbus</literal>.</para>
|
|
||||||
|
|
||||||
<para>If set to
|
<listitem><para>Configures the process
|
||||||
<literal>forking</literal>
|
start-up type for this service
|
||||||
(the default) it is expected
|
unit. One of <option>simple</option>,
|
||||||
that the process configured
|
<option>forking</option>,
|
||||||
with
|
<option>finish</option>,
|
||||||
<varname>ExecStart=</varname>
|
<option>dbus</option>,
|
||||||
will start up and call
|
<option>notify</option>.</para>
|
||||||
<function>fork()</function>. The
|
|
||||||
parent process is expected to
|
|
||||||
finish when start-up is
|
|
||||||
complete and all communication
|
|
||||||
channels set up. The child
|
|
||||||
continues to run as the main
|
|
||||||
daemon process. This is the
|
|
||||||
behaviour of traditional UNIX
|
|
||||||
daemons. If this setting is
|
|
||||||
used, it is recommended to also
|
|
||||||
use the
|
|
||||||
<varname>PIDFile=</varname>
|
|
||||||
option, so that systemd can
|
|
||||||
identify the main process of
|
|
||||||
the daemon. systemd will proceed
|
|
||||||
starting follow-up units as soon
|
|
||||||
as the parent process exits.</para>
|
|
||||||
|
|
||||||
<para>If set to
|
<para>If set to
|
||||||
<literal>simple</literal> (the
|
<option>simple</option> (the default
|
||||||
recommended value) it is
|
value) it is expected that the process
|
||||||
expected that the process
|
configured with
|
||||||
configured with
|
<varname>ExecStart=</varname> is the
|
||||||
<varname>ExecStart=</varname>
|
main process of the service. In this
|
||||||
is the main process of the
|
mode, communication channels must be
|
||||||
daemon. In this mode,
|
installed before the daemon is started
|
||||||
communication channels must be
|
up (e.g. sockets set up by systemd,
|
||||||
available before the daemon is
|
via socket activation), as systemd
|
||||||
started up (sockets set up by systemd),
|
will immediately proceed starting
|
||||||
as systemd will immediately proceed
|
follow-up units.</para>
|
||||||
starting follow-up units.</para>
|
|
||||||
|
|
||||||
<para>Behaviour of
|
<para>If set to
|
||||||
<literal>finish</literal> is
|
<option>forking</option> it is
|
||||||
similar to
|
expected that the process configured
|
||||||
<literal>simple</literal>,
|
with <varname>ExecStart=</varname>
|
||||||
however it is expected that
|
will start up and call
|
||||||
the process has to exit before
|
<function>fork()</function>. The
|
||||||
systemd starts follow-up
|
parent process is expected to finish
|
||||||
units. <varname>ValidNoProcess=</varname>
|
when start-up is complete and all
|
||||||
is particularly useful for
|
communication channels set up. The
|
||||||
this type of service.</para>
|
child continues to run as the main
|
||||||
|
daemon process. This is the behaviour
|
||||||
|
of traditional UNIX daemons. If this
|
||||||
|
setting is used, it is recommended to
|
||||||
|
also use the
|
||||||
|
<varname>PIDFile=</varname> option, so
|
||||||
|
that systemd can identify the main
|
||||||
|
process of the daemon. systemd will
|
||||||
|
proceed starting follow-up units as
|
||||||
|
soon as the parent process
|
||||||
|
exits.</para>
|
||||||
|
|
||||||
<para>Behaviour of
|
<para>Behaviour of
|
||||||
<literal>dbus</literal> is
|
<option>finish</option> is similar
|
||||||
similar to
|
to <option>simple</option>, however
|
||||||
<literal>simple</literal>,
|
it is expected that the process has to
|
||||||
however it is expected that
|
exit before systemd starts follow-up
|
||||||
the daemon acquires a name on
|
units. <varname>ValidNoProcess=</varname>
|
||||||
the D-Bus bus, as configured
|
is particularly useful for this type
|
||||||
by
|
of service.</para>
|
||||||
<varname>BusName=</varname>. Systemd will
|
|
||||||
proceed starting follow-up
|
<para>Behaviour of
|
||||||
units after the D-Bus bus name has been
|
<option>dbus</option> is similar to
|
||||||
acquired.</para>
|
<option>simple</option>, however it
|
||||||
|
is expected that the daemon acquires a
|
||||||
|
name on the D-Bus bus, as configured
|
||||||
|
by
|
||||||
|
<varname>BusName=</varname>. systemd
|
||||||
|
will proceed starting follow-up units
|
||||||
|
after the D-Bus bus name has been
|
||||||
|
acquired.</para>
|
||||||
|
|
||||||
|
<para>Behaviour of
|
||||||
|
<option>notify</option> is similar to
|
||||||
|
<option>simple</option>, however it is
|
||||||
|
expected that the daemon sends a
|
||||||
|
notification message via
|
||||||
|
<citerefentry><refentrytitle>sd_notify</refentrytitle><manvolnum>3</manvolnum></citerefentry>
|
||||||
|
or an equivalent call when it finished
|
||||||
|
starting up. systemd will proceed
|
||||||
|
starting follow-up units after this
|
||||||
|
notification message has been sent. If
|
||||||
|
this option is used
|
||||||
|
<option>NotifyAccess=</option> (see
|
||||||
|
below) must be set to open access to
|
||||||
|
the notification socket provided by
|
||||||
|
systemd.</para>
|
||||||
</listitem>
|
</listitem>
|
||||||
</varlistentry>
|
</varlistentry>
|
||||||
|
|
||||||
<varlistentry>
|
<varlistentry>
|
||||||
<term><varname>ValidNoProcess=</varname></term>
|
<term><varname>ValidNoProcess=</varname></term>
|
||||||
<listitem>
|
|
||||||
<para>Takes a boolean value
|
<listitem><para>Takes a boolean value
|
||||||
that specifies whether the service
|
that specifies whether the service
|
||||||
shall be considered active
|
shall be considered active even when
|
||||||
even when all its processes
|
all its processes exited. Defaults to
|
||||||
exited. Defaults to <literal>no</literal>.</para>
|
<option>no</option>.</para>
|
||||||
</listitem>
|
</listitem>
|
||||||
</varlistentry>
|
</varlistentry>
|
||||||
|
|
||||||
<varlistentry>
|
<varlistentry>
|
||||||
<term><varname>PIDFile=</varname></term>
|
<term><varname>PIDFile=</varname></term>
|
||||||
<listitem>
|
|
||||||
<para>Takes an absolute file
|
<listitem><para>Takes an absolute file
|
||||||
name pointing to the PID file
|
name pointing to the PID file of this
|
||||||
of this daemon. Use of this
|
daemon. Use of this option is
|
||||||
option is recommended for
|
recommended for services where
|
||||||
services where
|
<varname>Type=</varname> is set to
|
||||||
<varname>Type=</varname> is
|
<option>forking</option>.</para>
|
||||||
set to
|
|
||||||
<literal>forking</literal>.</para>
|
|
||||||
</listitem>
|
</listitem>
|
||||||
</varlistentry>
|
</varlistentry>
|
||||||
|
|
||||||
<varlistentry>
|
<varlistentry>
|
||||||
<term><varname>BusName=</varname></term>
|
<term><varname>BusName=</varname></term>
|
||||||
<listitem>
|
|
||||||
<para>Takes a D-Bus bus name,
|
<listitem><para>Takes a D-Bus bus
|
||||||
where this service is reachable
|
name, where this service is reachable
|
||||||
as. This option is mandatory
|
as. This option is mandatory for
|
||||||
for services where
|
services where
|
||||||
<varname>Type=</varname> is
|
<varname>Type=</varname> is set to
|
||||||
set to
|
<option>dbus</option>, but its use
|
||||||
<literal>dbus</literal>, but
|
is otherwise recommended as well if
|
||||||
its use is otherwise
|
the process takes a name on the D-Bus
|
||||||
recommended as well if the
|
bus.</para>
|
||||||
process takes a name on the
|
|
||||||
D-Bus bus.</para>
|
|
||||||
</listitem>
|
</listitem>
|
||||||
</varlistentry>
|
</varlistentry>
|
||||||
|
|
||||||
<varlistentry>
|
<varlistentry>
|
||||||
<term><varname>ExecStart=</varname></term>
|
<term><varname>ExecStart=</varname></term>
|
||||||
<listitem>
|
<listitem><para>Takes a command line
|
||||||
<para>Takes a command line
|
that is executed when this service
|
||||||
that is executed when this
|
shall be started up. The first token
|
||||||
service shall be started
|
of the command line must be an
|
||||||
up. The first word of the
|
absolute file name, then followed by
|
||||||
command line must be an
|
arguments for the process. It is
|
||||||
absolute file name. It is
|
mandatory to set this option for all
|
||||||
mandatory to set this option
|
services. This option may not be
|
||||||
for all services.</para>
|
specified more than once. Optionally,
|
||||||
</listitem>
|
if the absolute file name is prefixed
|
||||||
|
with @, the second token will be
|
||||||
|
passed as argv[0] to the executed
|
||||||
|
process, followed by the further
|
||||||
|
arguments specified. Unless
|
||||||
|
<option>Type=forking</option> is set,
|
||||||
|
the process started via this command
|
||||||
|
line will be considered the main
|
||||||
|
process of the
|
||||||
|
daemon.</para></listitem>
|
||||||
|
</varlistentry>
|
||||||
|
|
||||||
|
<varlistentry>
|
||||||
|
<term><varname>ExecStartPre=</varname></term>
|
||||||
|
<term><varname>ExecStartPost=</varname></term>
|
||||||
|
<listitem><para>Additional commands
|
||||||
|
that are executed before (resp. after)
|
||||||
|
the command in
|
||||||
|
<varname>ExecStart=</varname>. If
|
||||||
|
specified more than once, all commands
|
||||||
|
are executed one after the other,
|
||||||
|
serially. Use of these settings is
|
||||||
|
optional.</para></listitem>
|
||||||
|
</varlistentry>
|
||||||
|
|
||||||
|
<varlistentry>
|
||||||
|
<term><varname>ExecReload=</varname></term>
|
||||||
|
<listitem><para>Commands to execute to
|
||||||
|
trigger a configuration reload in the
|
||||||
|
service. If used more than once, all
|
||||||
|
commands are executed one after the
|
||||||
|
other, serially. Use of this setting is optional.
|
||||||
|
</para></listitem>
|
||||||
|
</varlistentry>
|
||||||
|
|
||||||
|
<varlistentry>
|
||||||
|
<term><varname>ExecStop=</varname></term>
|
||||||
|
<listitem><para>Commands to execute to
|
||||||
|
stop the service started via
|
||||||
|
<varname>ExecStart=</varname>. If used
|
||||||
|
more than once, all commands are
|
||||||
|
executed one after the other,
|
||||||
|
serially. Use of this setting is
|
||||||
|
optional. All processes remaining for
|
||||||
|
a service after the commands
|
||||||
|
configured in this option are run are
|
||||||
|
terminated according to the
|
||||||
|
<varname>KillMode=</varname> setting
|
||||||
|
(see below). If this option is not
|
||||||
|
specified the process is terminated
|
||||||
|
right-away when service stop is
|
||||||
|
requested.</para></listitem>
|
||||||
|
</varlistentry>
|
||||||
|
|
||||||
|
<varlistentry>
|
||||||
|
<term><varname>ExecStopPost=</varname></term>
|
||||||
|
<listitem><para>Additional commands
|
||||||
|
that are executed after the service
|
||||||
|
was stopped using the commands
|
||||||
|
configured in
|
||||||
|
<varname>ExecStop=</varname>. If
|
||||||
|
specified more than once, all commands
|
||||||
|
are executed one after the other,
|
||||||
|
serially. Use of these settings is
|
||||||
|
optional.</para></listitem>
|
||||||
|
</varlistentry>
|
||||||
|
|
||||||
|
<varlistentry>
|
||||||
|
<term><varname>RestartSec=</varname></term>
|
||||||
|
<listitem><para>Configures the time to
|
||||||
|
sleep before restarting a service (as
|
||||||
|
configured with
|
||||||
|
<varname>Restart=</varname>). Takes a
|
||||||
|
unit-less value in seconds, or a time
|
||||||
|
span value such as "5min
|
||||||
|
20s". Defaults to
|
||||||
|
100ms.</para></listitem>
|
||||||
|
</varlistentry>
|
||||||
|
|
||||||
|
<varlistentry>
|
||||||
|
<term><varname>TimeoutSec=</varname></term>
|
||||||
|
<listitem><para>Configures the time to
|
||||||
|
wait for start-up and stop. If a
|
||||||
|
daemon service does not signal
|
||||||
|
start-up completion within the
|
||||||
|
configured time the service will be
|
||||||
|
considered failed and be shut down
|
||||||
|
again. If a service is asked to stop
|
||||||
|
but does not terminate in the
|
||||||
|
specified time it will be terminated
|
||||||
|
forcibly via SIGTERM, and after
|
||||||
|
another delay of this time with
|
||||||
|
SIGKILL. (See
|
||||||
|
<option>KilleMode=</option>
|
||||||
|
below.) Takes a unit-less value in seconds, or a
|
||||||
|
time span value such as "5min
|
||||||
|
20s". Pass 0 to disable the timeout
|
||||||
|
logic. Defaults to
|
||||||
|
60s.</para></listitem>
|
||||||
|
</varlistentry>
|
||||||
|
|
||||||
|
<varlistentry>
|
||||||
|
<term><varname>Restart=</varname></term>
|
||||||
|
<listitem><para>Configures whether the
|
||||||
|
main service process shall be restarted when
|
||||||
|
it exists. Takes one of
|
||||||
|
<option>once</option>,
|
||||||
|
<option>restart-on-success</option> or
|
||||||
|
<option>restart-always</option>. If
|
||||||
|
set to <option>once</option> (the
|
||||||
|
default) the service will not be
|
||||||
|
restarted when it exits. If set to
|
||||||
|
<option>restart-on-success</option> it
|
||||||
|
will be restarted only when it exited
|
||||||
|
cleanly, i.e. terminated with an exit
|
||||||
|
code of 0. If set to
|
||||||
|
<option>restart-always</option> the
|
||||||
|
service will be restarted regardless
|
||||||
|
whether it exited cleanly or not, or
|
||||||
|
got terminated abnormally by a
|
||||||
|
signal.</para></listitem>
|
||||||
|
</varlistentry>
|
||||||
|
|
||||||
|
<varlistentry>
|
||||||
|
<term><varname>PermissionsStartOnly=</varname></term>
|
||||||
|
<listitem><para>Takes a boolean
|
||||||
|
argument. If true, the permission
|
||||||
|
related execution options as
|
||||||
|
configured with
|
||||||
|
<varname>User=</varname> and similar
|
||||||
|
options (see
|
||||||
|
<citerefentry><refentrytitle>systemd.exec</refentrytitle><manvolnum>5</manvolnum></citerefentry>
|
||||||
|
for more information) are only applied
|
||||||
|
to the process started with
|
||||||
|
<varname>ExecStart=</varname>, and not
|
||||||
|
to the various other
|
||||||
|
<varname>ExecStartPre=</varname>,
|
||||||
|
<varname>ExecStartPost=</varname>,
|
||||||
|
<varname>ExecReload=</varname>,
|
||||||
|
<varname>ExecStop=</varname>,
|
||||||
|
<varname>ExecStopPost=</varname>
|
||||||
|
commands. If false, the setting is
|
||||||
|
applied to all configured commands the
|
||||||
|
same way. Defaults to
|
||||||
|
false.</para></listitem>
|
||||||
|
</varlistentry>
|
||||||
|
|
||||||
|
<varlistentry>
|
||||||
|
<term><varname>RootDirectoryStartOnly=</varname></term>
|
||||||
|
<listitem><para>Takes a boolean
|
||||||
|
argument. If true, the root directory
|
||||||
|
as configured with the
|
||||||
|
<varname>RootDirectory=</varname>
|
||||||
|
option (see
|
||||||
|
<citerefentry><refentrytitle>systemd.exec</refentrytitle><manvolnum>5</manvolnum></citerefentry>
|
||||||
|
for more information) is only applied
|
||||||
|
to the process started with
|
||||||
|
<varname>ExecStart=</varname>, and not
|
||||||
|
to the various other
|
||||||
|
<varname>ExecStartPre=</varname>,
|
||||||
|
<varname>ExecStartPost=</varname>,
|
||||||
|
<varname>ExecReload=</varname>,
|
||||||
|
<varname>ExecStop=</varname>,
|
||||||
|
<varname>ExecStopPost=</varname>
|
||||||
|
commands. If false, the setting is
|
||||||
|
applied to all configured commands the
|
||||||
|
same way. Defaults to
|
||||||
|
false.</para></listitem>
|
||||||
|
</varlistentry>
|
||||||
|
|
||||||
|
<varlistentry>
|
||||||
|
<term><varname>SysVStartPriority=</varname></term>
|
||||||
|
<listitem><para>Set the SysV start
|
||||||
|
priority to use to order this service
|
||||||
|
in relation to SysV services lacking
|
||||||
|
LSB headers. This option is only
|
||||||
|
necessary to fix ordering in relation
|
||||||
|
to legacy SysV services, that have no
|
||||||
|
ordering information encoded in the
|
||||||
|
script headers. As such it should only
|
||||||
|
be used as temporary compatibility
|
||||||
|
option, and not be used in new unit
|
||||||
|
files. Almost always it is a better
|
||||||
|
choice to add explicit ordering
|
||||||
|
directives via
|
||||||
|
<varname>After=</varname> or
|
||||||
|
<varname>Before=</varname>,
|
||||||
|
instead. For more details see
|
||||||
|
<citerefentry><refentrytitle>systemd.unit</refentrytitle><manvolnum>5</manvolnum></citerefentry>. If
|
||||||
|
used, pass an integer value in the
|
||||||
|
range 0-99.</para></listitem>
|
||||||
|
</varlistentry>
|
||||||
|
|
||||||
|
<varlistentry>
|
||||||
|
<term><varname>KillMode=</varname></term>
|
||||||
|
<listitem><para>Specifies how
|
||||||
|
processes of this service shall be
|
||||||
|
killed. One of
|
||||||
|
<option>control-group</option>,
|
||||||
|
<option>process-group</option>,
|
||||||
|
<option>process</option>,
|
||||||
|
<option>none</option>.</para>
|
||||||
|
|
||||||
|
<para>If set to
|
||||||
|
<option>control-group</option> all
|
||||||
|
remaining processes in the control
|
||||||
|
group of this service will be
|
||||||
|
terminated on service stop, after the
|
||||||
|
stop command (as configured with
|
||||||
|
<varname>ExecStop=</varname>) is
|
||||||
|
executed. If set to
|
||||||
|
<option>process-group</option> only
|
||||||
|
the members of the process group of
|
||||||
|
the main service process are
|
||||||
|
killed. If set to
|
||||||
|
<option>process</option> only the main
|
||||||
|
process itself is killed. If set to
|
||||||
|
<option>none</option> no process is
|
||||||
|
killed. In this case only the stop
|
||||||
|
command will be executed on service
|
||||||
|
stop, but no process be killed
|
||||||
|
otherwise. Processes remaining alive
|
||||||
|
after stop are left in their control
|
||||||
|
group and the control group continues
|
||||||
|
to exist after stop unless it is
|
||||||
|
empty. Defaults to
|
||||||
|
<option>control-croup</option>.</para>
|
||||||
|
|
||||||
|
<para>Processes will first be
|
||||||
|
terminated via SIGTERM. If then after
|
||||||
|
a delay (configured via the
|
||||||
|
<option>TimeoutSec=</option> option)
|
||||||
|
processes still remain, the
|
||||||
|
termination request is repeated with
|
||||||
|
the SIGKILL signal. See
|
||||||
|
<citerefentry><refentrytitle>kill</refentrytitle><manvolnum>2</manvolnum></citerefentry>
|
||||||
|
for more
|
||||||
|
information.</para></listitem>
|
||||||
|
</varlistentry>
|
||||||
|
|
||||||
|
<varlistentry>
|
||||||
|
<term><varname>NonBlocking=</varname></term>
|
||||||
|
<listitem><para>Set O_NONBLOCK flag
|
||||||
|
for all file descriptors passed via
|
||||||
|
socket-based activation. If true, all
|
||||||
|
file descriptors >= 3 (i.e. all except
|
||||||
|
STDIN/STDOUT/STDERR) will have
|
||||||
|
the O_NONBLOCK flag set and hence are in
|
||||||
|
non-blocking mode. This option is only
|
||||||
|
useful in conjunction with a socket
|
||||||
|
unit, as described in
|
||||||
|
<citerefentry><refentrytitle>systemd.socket</refentrytitle><manvolnum>5</manvolnum></citerefentry>. Defaults
|
||||||
|
to false.</para></listitem>
|
||||||
|
</varlistentry>
|
||||||
|
|
||||||
|
<varlistentry>
|
||||||
|
<term><varname>NotifyAccess=</varname></term>
|
||||||
|
<listitem><para>Controls access to the
|
||||||
|
service status notification socket, as
|
||||||
|
accessible via the
|
||||||
|
<citerefentry><refentrytitle>sd_notify</refentrytitle><manvolnum>3</manvolnum></citerefentry>
|
||||||
|
call. Takes one of
|
||||||
|
<option>none</option> (the default),
|
||||||
|
<option>main</option> or
|
||||||
|
<option>all</option>. If
|
||||||
|
<option>none</option> no daemon status
|
||||||
|
updates are accepted by the service
|
||||||
|
processes, all status update messages
|
||||||
|
are ignored. If <option>main</option>
|
||||||
|
only service updates sent from the
|
||||||
|
main process of the service are
|
||||||
|
accepted. If <option>all</option> all
|
||||||
|
services updates from all members of
|
||||||
|
the service's control group are
|
||||||
|
accepted. This option must be set to
|
||||||
|
open access to the notification socket
|
||||||
|
when using
|
||||||
|
<varname>Type=notify</varname> (see above).</para></listitem>
|
||||||
</varlistentry>
|
</varlistentry>
|
||||||
|
|
||||||
</variablelist>
|
</variablelist>
|
||||||
@ -205,8 +502,9 @@
|
|||||||
<title>See Also</title>
|
<title>See Also</title>
|
||||||
<para>
|
<para>
|
||||||
<citerefentry><refentrytitle>systemd</refentrytitle><manvolnum>8</manvolnum></citerefentry>,
|
<citerefentry><refentrytitle>systemd</refentrytitle><manvolnum>8</manvolnum></citerefentry>,
|
||||||
<citerefentry><refentrytitle>systemctl</refentrytitle><manvolnum>8</manvolnum></citerefentry>
|
<citerefentry><refentrytitle>systemctl</refentrytitle><manvolnum>8</manvolnum></citerefentry>,
|
||||||
<citerefentry><refentrytitle>systemd.unit</refentrytitle><manvolnum>5</manvolnum></citerefentry>
|
<citerefentry><refentrytitle>systemd.unit</refentrytitle><manvolnum>5</manvolnum></citerefentry>,
|
||||||
|
<citerefentry><refentrytitle>systemd.exec</refentrytitle><manvolnum>5</manvolnum></citerefentry>
|
||||||
</para>
|
</para>
|
||||||
</refsect1>
|
</refsect1>
|
||||||
|
|
||||||
|
@ -246,8 +246,8 @@
|
|||||||
mounts listed in
|
mounts listed in
|
||||||
<filename>/etc/fstab</filename>
|
<filename>/etc/fstab</filename>
|
||||||
that have the
|
that have the
|
||||||
<literal>auto</literal> and
|
<option>auto</option> and
|
||||||
<literal>comment=systemd.mount</literal>
|
<option>comment=systemd.mount</option>
|
||||||
mount options set.</para>
|
mount options set.</para>
|
||||||
|
|
||||||
<para>systemd automatically
|
<para>systemd automatically
|
||||||
|
@ -102,6 +102,16 @@
|
|||||||
<option>false</option> and <option>off</option> are
|
<option>false</option> and <option>off</option> are
|
||||||
equivalent.</para>
|
equivalent.</para>
|
||||||
|
|
||||||
|
<para>Time span values encoded in unit files can be
|
||||||
|
written in various formats. A stand-alone number
|
||||||
|
specifies a time in seconds. If suffixed with a time
|
||||||
|
unit, the unit is honored. A concatentation of
|
||||||
|
multiple value with units is supported, in which case
|
||||||
|
the values are added up. Example: "50" refers to 50
|
||||||
|
seconds; "2min 200ms" refers to 2 minutes plus 200
|
||||||
|
milliseconds, i.e. 120200ms. The following time units
|
||||||
|
are understood: s, min, h, d, w, ms, us.</para>
|
||||||
|
|
||||||
<para>Empty lines and lines starting with # or ; are
|
<para>Empty lines and lines starting with # or ; are
|
||||||
ignored. This may be used for commenting.</para>
|
ignored. This may be used for commenting.</para>
|
||||||
|
|
||||||
|
@ -2625,8 +2625,8 @@ static const char* const service_restart_table[_SERVICE_RESTART_MAX] = {
|
|||||||
DEFINE_STRING_TABLE_LOOKUP(service_restart, ServiceRestart);
|
DEFINE_STRING_TABLE_LOOKUP(service_restart, ServiceRestart);
|
||||||
|
|
||||||
static const char* const service_type_table[_SERVICE_TYPE_MAX] = {
|
static const char* const service_type_table[_SERVICE_TYPE_MAX] = {
|
||||||
[SERVICE_FORKING] = "forking",
|
|
||||||
[SERVICE_SIMPLE] = "simple",
|
[SERVICE_SIMPLE] = "simple",
|
||||||
|
[SERVICE_FORKING] = "forking",
|
||||||
[SERVICE_FINISH] = "finish",
|
[SERVICE_FINISH] = "finish",
|
||||||
[SERVICE_DBUS] = "dbus",
|
[SERVICE_DBUS] = "dbus",
|
||||||
[SERVICE_NOTIFY] = "notify"
|
[SERVICE_NOTIFY] = "notify"
|
||||||
|
Loading…
Reference in New Issue
Block a user